Takara Tetracycline-inducible adenovirus system

Takara Bio`s Clontech-brand Adeno-X Adenoviral System 3 (Tet-On 3G Inducible) combines the tightest and most sensitive control of gene expression with the most advanced commercially available adenoviral vector system. With this system, tightly controlled inducible expression is as easy as constitutive expression, and cloning into an adenoviral vector is as straightforward as cloning into any plasmid.

Takara Bio`s Clontech-brand Adeno-X Adenoviral System 3 (Tet-On 3G Inducible) combines the tightest and most sensitive control of gene expression with the most advanced commercially available adenoviral vector system. With this system, the tightly controlled inducible expression is as easy as constitutive expression, and cloning into an adenoviral vector is as straightforward as cloning into any plasmid.

How does the Tet-On 3G inducible system work?

Target cells that express the Tet-On 3G transactivator protein and contain a gene of interest (GOI) under the control of a TRE3G promoter (PTRE3G) will express high levels of your GOI, but only when cultured in the presence of doxycycline (Dox), a tetracycline analog. When bound by Dox, the Tet-On 3G protein undergoes a conformational change that allows it to bind to tet operator (tetO) sequences located in PTRE3G (please expand the Details tab in the product table for more information). In contrast to TetR-based systems, Tet-On technologies activate rather than repress transcription, a critical difference which results in far lower basal expression, higher maximal expression, a more rapid response time, and ultimately, the first choice for conditional expression.

What makes this system so easy to use?

  1. All-in-one vector—The Tet-On 3G transactivator gene has been precloned into the E3 region of the adenoviral genome and is expressed constitutively from a CMV promoter. Clone your gene of interest using In-Fusion HD at the E1 region of the adenovirus between the tightly regulated PTRE3G promoter and an SV40 polyA signal. Because the two regions are widely separated, interference from the CMV promoter cannot affect basal expression from PTRE3G, and so a very low basal expression and high fold-inducibility are retained (see data images by expanding the Details tab in the product table).
  2. Easy cloning—Until now the main drawback of commercially supplied adenoviral vector systems has been the need to use complex cloning procedures to overcome the difficulties with cloning into large (~34 kb) plasmids. Our Adeno-X virologists thought wouldnt it be great if you could clone directly into the adenoviral plasmid just like any plasmid?` They then harnessed the power of In-Fusion HD Cloning technology to make this happen.

Lowest-ever background, highest sensitivity

The combination of two optimized elements makes Tet-On 3G the highest performing inducible expression system.

  1. PTRE3G promoter—Mutations have reduced background expression from the inducible promoter to very low levels compared to previous generations of the Tet-On system.
  2. Tet-On 3G transactivator protein—Compared to early generations, mutations have significantly increased its sensitivity to the inducer doxycycline. When the two elements are combined, not only can you detect high expression of your protein after exposure to Dox, you can control the level of expression by titration of the Dox concentration, and you can generate very high fold induction—up to a 3,000-fold difference between the induced and uninduced states. The maximum expression level can be manipulated by increasing the amount of virus per cell (see data included under the Details tab).

Unlike the leading competitor, Adeno-X really is easy

Compared to the leading competitor system, which requires 8 days or more for a cloning procedure that involves cloning into a shuttle vector and transformation of two different E. coli strains, the Adeno-X system is easy and allows you to finish cloning with high efficiency in just 2–3 days. Adeno-X uses no shuttle vector so requires no subcloning, and a single high-performance E. coli strain (Stellar) is included with the kit.

More Less


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드 결제 (결제링크 문자+이메일 전송)
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0