
Thermo Fisher Scientific CD247 (CD3 zeta) Monoclonal Antibody (6B10.2), PerCP-eFluor 710, eBioscience
인간 CD247(CD3 zeta) 단백질을 인식하는 마우스 모노클론 항체로, PerCP-eFluor 710 형광체로 결합됨. 세포내 염색 후 유세포분석(Flow Cytometry)에 적합. T세포 활성화 신호 전달 연구에 유용. 빛에 민감하며 4°C에서 보관.
- 카탈로그번호
- 46-2479-42
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD247 (CD3 zeta) Monoclonal Antibody (6B10.2), PerCP-eFluor 710, eBioscience
Applications and Tested Dilution
| Application | Tested Dilution |
|---|---|
| Flow Cytometry (Flow) | 5 µL (0.03 µg)/test |
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Recommended Isotype Control | Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), PerCP-eFluor™ 710, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 6B10.2 |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation/Emission Max | 482/708 nm |
| Form | Liquid |
| Concentration | 5 µL/test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2, with 0.2% BSA |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_2573736 |
Additional Formats:
Product Specific Information
The 6B10.2 monoclonal antibody reacts with human CD247 (CD3 zeta chain). The CD3 complex consists of gamma, delta, epsilon, and zeta chains, forming part of the TCR/CD3 complex. CD3 zeta is expressed on immature and mature thymocytes, T lymphocytes, and NK cells. It plays a key role in T cell activation via tyrosine phosphorylation of ITAM motifs.
This antibody recognizes a transmembrane epitope of the CD3 zeta chain; therefore, intracellular staining is required for flow cytometric analysis. It detects the zeta chain as a homodimer but not as a monomer.
Applications Reported:
Intracellular staining followed by flow cytometric analysis.
Applications Tested:
Pre-titrated and tested using the Intracellular Fixation & Permeabilization Buffer Set (Product #88-8824-00) following BestProtocols® Protocol A.
Use 5 µL (0.03 µg) per test in 100 µL volume, with 10⁵–10⁸ cells/test.
Fluorochrome Information:
PerCP-eFluor® 710 emits at 710 nm, excited by the 488 nm blue laser. Recommended filter: 710/50 bandpass (695/40 acceptable). Protect from light due to photo-induced oxidation sensitivity.
Fixation:
Samples can be stored in IC Fixation Buffer (Product #00-8222) or 1-step Fix/Lyse Solution (Product #00-5333) for up to 3 days at 4°C in the dark.
Excitation: 488 nm
Emission: 710 nm
Laser: Blue Laser
Filtration: 0.2 µm post-manufacturing filtered
Target Information
The CD3z complex is essential for transducing antigen recognition signals into T cells and regulating TCR complex expression. CD3 subunits (gamma, delta, epsilon, zeta) are encoded on chromosome 11 and contain ITAM motifs for signal transduction. CD3 is expressed on most T lymphocytes and thymocytes, but not on B or NK cells. Altered CD3 expression is associated with immune deficiencies such as Immunodeficiency 25 and T-B+ Severe Combined Immunodeficiency due to CD3δ/ε/ζ defects.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
