
Thermo Fisher Scientific CD244 Monoclonal Antibody (eBioC1.7 (C1.7)), NovaFluor Red 755, eBioscience
인간 CD244(2B4, SLAMF4) 검출용 단클론 항체로, NovaFluor Red 755 형광 표지. NK 및 T 세포 분석에 적합하며, 흐름세포분석(Flow Cytometry)에 최적화. CellBlox Plus Blocking Buffer 포함, 4°C 암소 보관.
- 카탈로그번호
- H080T0xxxxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD244 Monoclonal Antibody (eBioC1.7 (C1.7)), NovaFluor Red 755, eBioscience
Applications
- Flow Cytometry (Flow)
- Tested Dilution: 5 µL (0.4 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | eBioC1.7 (C1.7) |
| Conjugate | NovaFluor™ Red 755 |
| Excitation / Emission Max | 636 / 755 nm |
| Form | Liquid |
| Concentration | 0.4 µg/Test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2, with BSA |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
Additional Formats
- Biotin
- Functional Grade
- NovaFluor Blue 660-120S
- NovaFluor Red 685
- NovaFluor Red 700
- NovaFluor Yellow 610
- NovaFluor Yellow 660
- NovaFluor Yellow 700
- PE
- PE-Cyanine5.5
- Super Bright 436
- Super Bright 600
- Super Bright 645
- Request custom conjugation
Product Specific Information
Description:
The eBioC1.7 monoclonal antibody reacts with human CD244 (2B4, p38), a 38 kDa protein expressed on NK cells, subsets of CD8⁺ T cells, γδ T cells, monocytes, basophils, and eosinophils. CD244 binds to CD48, resulting in NK cell activation and enhanced cytotoxicity. C1.7 binding induces tyrosine phosphorylation and SAP recruitment. In X-linked lymphoproliferative disorder (XLPD), SAP mutations impair this interaction.
Applications Reported:
- Reported for use in flow cytometric analysis.
Applications Tested:
- Pre-diluted and tested by flow cytometry on normal human peripheral blood cells.
- Use 5 µL (0.4 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).
Each product includes:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) must be used for optimal staining.
- Add 5 µL per sample before combining with cells.
- For single-color controls, add 5 µL per 100 µL of cell sample.
NovaFluor Conjugate Technology:
NovaFluor conjugates utilize Phiton™ technology with engineered nucleic acid dye structures to optimize fluorescent performance and minimize spillover.
Optical Properties:
- Excitation: 636 nm
- Emission: 756 nm
- Laser: 633–640 nm (Red)
Target Information
CD244 (2B4, SLAMF4) is a cell surface receptor on NK cells and some T cells that mediates non-MHC-restricted cytotoxicity. Interaction with SLAMF2 activates both SLAMF4- and SLAMF2-expressing cells. Reduced SLAMF4 levels are observed in systemic lupus erythematosus, implicating CD244 in autoimmune disease pathology. CD244 dysfunction is associated with rheumatoid arthritis and lymphoproliferative syndromes. Multiple transcript variants exist.
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
