
Thermo Fisher Scientific GL7 Monoclonal Antibody (GL-7 (GL7)), eFluor 450, eBioscience
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Applications
Tested Dilution
Publications
Immunohistochemistry (IHC)
-
View 3 publications 3 publications
Immunocytochemistry (ICC/IF)
-
View 2 publications 2 publications
Flow Cytometry (Flow)
0.5 µg/test
View 31 publications 31 publications
Functional Assay (Functional)
-
View 1 publication 1 publication
Product Specifications
Species Reactivity
Human, Mouse
Published species
Human, Mouse
Host/Isotype
Rat / IgM
Recommended Isotype Control
Rat IgM Isotype Control (eBRM), eFluor™ 450, eBioscience™
Class
Monoclonal
Type
Antibody
Clone
GL-7 (GL7)
Conjugate
eFluor™ 450 eFluor™ 450 eFluor™ 450
View additional formats
Excitation/Emission Max
405/445 nm View spectra
Form
Liquid
Concentration
0.2 mg/mL
Purification
Affinity chromatography
Storage buffer
PBS, pH 7.2
Contains
0.09% sodium azide
Storage conditions
4° C, store in dark, DO NOT FREEZE!
Shipping conditions
Ambient (domestic); Wet ice (international)
RRID
AB_10854881
Product Specific Information
Description: This GL7 monoclonal antibody reacts with a cell-surface protein found on T and B lymphocytes activated in vitro, on bone marrow pre-B-II cells, germinal center B cells, and also human B cell lines Ramos and Daudi. There is strain variability with respect to antigen distribution on thymocytes and Con A-activated spleen cells, with expression in BALB/c greater than that in C57BL/6. GL7 is commonly used as a marker for mouse germinal center B cells. The epitope of GL7 has been identified as a sialic acid glycan moiety called Neu5Ac. This moiety is recognized by CD22.
Applications Reported: This GL-7 (GL7) antibody has been reported for use in flow cytometric analysis.
Applications Tested: This GL-7 (GL7) antibody has been tested by flow cytometric analysis of stimulated mouse splenocytes. This can be used at less than or equal to 0.5 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.
eFluor® 450 is an alternative to Pacific Blue®. eFluor® 450 emits at 445 nm and is excited with the Violet laser (405 nm). Please make sure that your instrument is capable of detecting this fluorochome.
Excitation: 405 nm; Emission: 445 nm; Laser: Violet Laser.
Filtration: 0.2 µm post-manufacturing filtered.
Target Information
GL7 is a cell-surface protein found on T and B lymphocytes activated in vitro, on bone marrow pre-B-II cells, germinal center B cells, and also human B cell lines Ramos and Daudi. There is strain variability with respect to antigen distribution on thymocytes and Con A-activated spleen cells, with expression in BALB/c greater than that in C57BL/6. GL7 is commonly used as a marker for mouse germinal center B cells. The epitope of GL7 has been identified as a sialic acid glycan moiety called Neu5Ac. This moiety is recognized by CD22.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific TER-119 Monoclonal Antibody (TER-119), eFluor 450, eBioscience
252,200원

Thermo Fisher Scientific
Thermo Fisher Scientific MHC Class I (H-2Kk) Monoclonal Antibody (AF3-12.1.3), eFluor 450, eBioscience
141,500원

Thermo Fisher Scientific
Thermo Fisher Scientific GL7 Monoclonal Antibody (GL-7 (GL7)), eFluor 450, eBioscience
184,800원

Thermo Fisher Scientific
Thermo Fisher Scientific KLRG1 Monoclonal Antibody (2F1), eFluor 450, eBioscience
495,600원

Thermo Fisher Scientific
Thermo Fisher Scientific CD93 (AA4.1) Monoclonal Antibody (AA4.1), eFluor 450, eBioscience
156,400원
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제수단 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|