CacheBy
Thermo Fisher Scientific CD62E (E-selectin) Monoclonal Antibody (P2H3), PE, eBioscience
원본

Thermo Fisher Scientific CD62E (E-selectin) Monoclonal Antibody (P2H3), PE, eBioscience

상품 한눈에 보기

인간 CD62E(E-selectin)을 인식하는 P2H3 클론 단일클론 항체로, PE 형광표지되어 있습니다. 흐름세포분석(Flow Cytometry)에 최적화되어 있으며, 염증 시 세포 부착 관련 연구에 활용됩니다. 4°C 암소 보관, 동결 금지.

카탈로그번호
12-0627-4x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 02. 오후 09:37
Thermo Fisher Scientific 12-0627-42 CD62E (E-selectin) Monoclonal Antibody (P2H3), PE, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
564,100원VAT 포함 620,510원
Thermo Fisher Scientific 12-0627-41 CD62E (E-selectin) Monoclonal Antibody (P2H3), PE, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
198,500원VAT 포함 218,350원

Thermo Fisher Scientific · Thermo Fisher Scientific CD62E (E-selectin) Monoclonal Antibody (P2H3), PE, eBioscience

Thermo Fisher Scientific CD62E (E-selectin) Monoclonal Antibody (P2H3), PE, eBioscience™

Applications and Tested Dilution

Application Tested Dilution Publications
Immunocytochemistry (ICC/IF) - View 1 publication
Flow Cytometry (Flow) 5 µL (0.5 µg)/test View 7 publications

Product Specifications

항목 내용
Species Reactivity Human
Published Species Human
Host / Isotype Mouse / IgG1
Recommended Isotype Control Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), PE, eBioscience™
Class Monoclonal
Type Antibody
Clone P2H3
Conjugate PE
Excitation / Emission Max 565 / 576 nm
Form Liquid
Concentration 5 µL/test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_11217891

Product Specific Information

The P2H3 monoclonal antibody reacts with human CD62E, a 97–115 kDa member of the selectin family. CD62E (E-selectin or ELAM-1) is an adhesion molecule expressed by endothelial cells upon stimulation with cytokines such as TNFα and IL-1β.
Induced expression of CD62E during inflammatory conditions mediates leukocyte rolling and initial neutrophil-endothelium interaction.
This antibody inhibits cellular adhesion to cytokine-activated endothelial cells.

Applications Reported: Flow cytometric analysis.
Applications Tested: Pre-titrated and validated for flow cytometry with TNFα-activated HUVEC cells. Recommended use at 5 µL (0.5 µg) per test (100 µL final volume).
Cell number may range from 10⁵ to 10⁸ cells/test.

Optical Properties:

  • Excitation: 488–561 nm
  • Emission: 578 nm
  • Compatible Lasers: Blue, Green, Yellow-Green
  • Filtration: 0.2 µm post-manufacturing filtered

Target Information

Leukocyte adhesion to endothelium occurs during inflammation and involves selectin and immunoglobulin superfamily receptors.
E-selectin (CD62E) is expressed by endothelial cells only after activation with proinflammatory cytokines.
Induced by IL-1, TNFα, and bacterial lipopolysaccharides through NFκB-dependent transcription.
E-selectin is associated with vascular endothelium in various inflammatory responses.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.