Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Yellow 660, eBioscience
인간 CD4 항원에 특이적인 OKT4 단클론 항체로, NovaFluor Yellow 660 형광체가 결합된 제품입니다. Flow Cytometry 분석용으로 검증되었으며, CellBlox Plus Blocking Buffer와 함께 제공되어 최적의 형광 신호를 보장합니다. 연구용으로만 사용 가능합니다.
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Yellow 660, eBioscience
Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Yellow 660, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.6 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host/Isotype | Mouse / IgG2b, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | OKT4 (OKT-4) |
| Conjugate | NovaFluor™ Yellow 660 |
| Excitation/Emission Max | 550/664 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098403 (AB_2910774) |
Additional Formats Available
- Unconjugated
- Alexa Fluor 488
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV 661
- Brilliant Violet 650
- Brilliant Violet 786
- eFluor 450
- eFluor 660
- FITC
- Functional Grade
- NovaFluor Blue 610-70S
- NovaFluor Blue 660-120S
- NovaFluor Blue 690
- PE
- PE-Cyanine7
- PerCP-Cyanine5.5
- Super Bright 436
- Super Bright 600
- Super Bright 702
- Request custom conjugation
Product Specific Information
The OKT4 monoclonal antibody reacts with human CD4, a 59 kDa cell surface glycoprotein expressed by thymocytes, mature T-helper cells, and monocytes. CD4 acts as a receptor for HIV. The OKT4 antibody recognizes a distinct epitope from the RPA-T4 antibody and does not cross-block.
Each product includes one vial of NovaFluor conjugate and one vial of CellBlox Plus Blocking Buffer.
Applications Reported:
- Suitable for flow cytometric analysis.
Applications Tested:
- Tested on normal human peripheral blood cells.
- Use ≤5 µL (0.6 µg) per test (100 µL final volume).
- Recommended to titrate for optimal performance.
- Cell range: 10⁵–10⁸ cells/test.
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains instead.
- For optimal staining, use CellBlox Plus Blocking Buffer (Cat. No. C001T06F01).
- Add 5 µL of blocking buffer per sample before combining with cells.
- For single-color controls, use 5 µL per 100 µL cell sample containing 10³–10⁸ cells.
NovaFluor conjugates utilize Phiton™ technology with engineered fluorescent signatures to minimize spillover and spread.
Excitation: 552 nm
Emission: 663 nm
Laser: 561 nm (Yellow)
Target Information
CD4 is a co-receptor for MHC class II molecules and HIV. It is expressed in T-helper cells, monocytes, macrophages, and dendritic cells. At the tissue level, CD4 is found in thymus, lymph nodes, tonsils, spleen, and certain regions of the brain and gut. It plays a role in T-cell activation via association with the TCR complex and tyrosine kinase Lck. CD4 may also mediate neuronal damage in immune-related CNS diseases. Multiple alternatively spliced transcripts are known (RefSeq, July 2017).
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.