
Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Blue 660-120S, eBioscience
인간 CD4 항원 인식용 OKT4 단클론 항체로, NovaFluor Blue 660-120S 형광체가 결합된 제품입니다. Flow Cytometry 분석에 최적화되어 있으며 CellBlox Plus Blocking Buffer와 함께 사용 시 최적의 염색 성능을 제공합니다. 연구용으로만 사용 가능합니다.
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Blue 660-120S, eBioscience
Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Blue 660-120S
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (1.0 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG2b, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | OKT4 (OKT-4) |
| Conjugate | NovaFluor™ Blue 660-120S |
| Excitation / Emission Max | 492 / 665 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE |
| RRID | AB_3098401 (AB_2910773) |
Additional Available Formats
- Unconjugated
- Alexa Fluor 488
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV 661
- Brilliant Violet 650
- Brilliant Violet 786
- eFluor 450
- eFluor 660
- FITC
- Functional Grade
- NovaFluor Blue 610-70S
- NovaFluor Blue 690
- NovaFluor Yellow 660
- PE
- PE-Cyanine7
- PerCP-Cyanine5.5
- Super Bright 436
- Super Bright 600
- Super Bright 702
- Request custom conjugation
Product Specific Information
The OKT4 monoclonal antibody reacts with human CD4, a 59 kDa cell surface glycoprotein expressed by the majority of thymocytes, a subpopulation of mature T cells (T-helper cells), and at low levels on monocytes. CD4 is a receptor for HIV. The OKT4 antibody recognizes a different epitope than the RPA-T4 monoclonal antibody, and these antibodies do not cross-block each other.
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Tested on normal human peripheral blood cells. Recommended ≤5 µL (1.0 µg) per test in 100 µL final volume. Cell number range: 10⁵–10⁸ cells/test.
Usage Notes:
- Carefully titrate for optimal performance.
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains with NovaFluor dyes.
CellBlox Plus Blocking Buffer (Cat. No. C001T06F01):
- Improved formulation over CellBlox.
- Required for optimal staining with NovaFluor conjugates.
- Add 5 µL per sample to antibody cocktails or single-color controls (100 µL cell sample, 10³–10⁸ cells).
NovaFluor conjugates utilize Phiton technology with engineered fluorescent signatures optimized for minimal spillover and spread impacts.
Excitation: 509 nm; Emission: 665 nm; Laser: 488 nm (Blue)
Target Information
CD4 antigen is involved in recognition of MHC class II molecules and acts as a co-receptor for HIV. CD4 is primarily expressed in T-helper cells but also in monocytes, macrophages, and dendritic cells. Expression is observed in thymus, lymph nodes, tonsils, spleen, and certain non-lymphoid tissues such as brain and gut. CD4 contributes to T-cell activation and may mediate neuronal damage in infectious or immune diseases of the CNS. Multiple alternatively spliced transcripts identified (RefSeq, July 2017).
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
