CacheBy
Thermo Fisher Scientific CD16/CD32 Monoclonal Antibody (93), NovaFluor Red 755, eBioscience
원본

Thermo Fisher Scientific CD16/CD32 Monoclonal Antibody (93), NovaFluor Red 755, eBioscience

상품 한눈에 보기

마우스 CD16/CD32 인식 단클론 항체(클론 93)로, NovaFluor Red 755 형광체 결합. Flow cytometry에 최적화되어 있으며 CellBlox Plus Blocking Buffer 포함. 636/755 nm 파장에서 작동하며, 비호환 염색제 주의 필요. 연구용 전용.

카탈로그번호
M021T0xxxx (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 10:10
Thermo Fisher Scientific M021T03R06 CD16/CD32 Monoclonal Antibody (93), NovaFluor Red 755, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
591,100원VAT 포함 650,210원
Thermo Fisher Scientific M021T02R06 CD16/CD32 Monoclonal Antibody (93), NovaFluor Red 755, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
304,800원VAT 포함 335,280원

Thermo Fisher Scientific · Thermo Fisher Scientific CD16/CD32 Monoclonal Antibody (93), NovaFluor Red 755, eBioscience

Applications

  • Flow Cytometry (Flow): Tested at ≤ 1.0 µg/test

Product Specifications

항목 내용
Species Reactivity Mouse
Host / Isotype Rat / IgG2a, lambda
Class Monoclonal
Type Antibody
Clone 93
Conjugate NovaFluor™ Red 755
Excitation / Emission Max 636 / 755 nm
Form Liquid
Concentration 0.1 mg/mL
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
RRID AB_3099015 (AB_2931019)

Additional Available Formats

  • Unconjugated
  • Alexa Fluor 700
  • APC
  • Biotin
  • Brilliant UV 496
  • Brilliant UV 661
  • eFluor 450
  • FITC
  • Functional Grade
  • NovaFluor Red 685
  • NovaFluor Red 700
  • NovaFluor Red 710
  • NovaFluor Yellow 690
  • PE
  • PE-Cyanine7
  • PerCP-Cyanine5.5
  • PerCP-eFluor 710
  • Super Bright 436
  • Super Bright 600
  • Request custom conjugation

Product Specific Information

Description:
The 93 monoclonal antibody binds to an epitope shared by mouse CD16 and CD32.
CD16 (FcγRIII) and CD32 (FcγRII) are low-affinity receptors for the Fc portion of mouse IgG, expressed on B cells, monocytes/macrophages, NK cells, and neutrophils.

Each product includes:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported: Flow cytometric analysis
Applications Tested: Mouse splenocytes, ≤1.0 µg/test (100 µL final volume, 10⁵–10⁸ cells/test).
Optimize antibody titration for best performance.

Important Notes:

  • NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
  • Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for compatibility.
  • CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) must be used for optimal staining.
    • Add 5 µL per sample (regardless of the number of NovaFluor dyes).
    • For single-color controls: 5 µL per 100 µL of cell sample (10³–10⁸ cells).

NovaFluor conjugates use Phiton™ technology, employing nucleic acid dye structures engineered for optimal fluorescence and minimal spectral spillover.

Excitation: 636 nm
Emission: 756 nm
Laser: 633–640 nm (Red)


Target Information

CD16 (FcγRIII):

  • 50–65 kDa cell surface molecule
  • Expressed as transmembrane (NK, some T cells) and GPI-linked (granulocytes) forms
  • Mediates antibody-dependent cell-mediated cytotoxicity (ADCC)

CD32 (FcγRII):

  • 40 kDa glycoprotein
  • Low-affinity IgG receptor
  • Functions: endocytosis, secretion activation, cytotoxicity, immunomodulation
  • Expressed on B cells, monocytes, granulocytes, platelets
  • Involved in phagocytosis of immune complexes and antibody production regulation
  • Gene variations may increase susceptibility to systemic lupus erythematosus (SLE)
  • Multiple transcript variants exist

For Research Use Only. Not for use in diagnostic procedures. Not for resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.