Thermo Fisher Scientific Pathatrix Auto Instrument

상품 옵션 정보
카탈로그 번호CAS 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
PATHATRIXAUTO-Thermo Fisher Scientific PATHATRIXAUTO Pathatrix Auto Instrument Each pk재고문의pk0-0

Applied Biosystems™

Pathatrix™ Auto Instrument

The Pathatrix™ Auto Instrument quickly and easily concentrates pathogens and spoilage organisms from a wide range of food and environmental자세히 알아보기

The Pathatrix™ Auto Instrument quickly and easily concentrates pathogens and spoilage organisms from a wide range of food and environmental sample matrices for downstream testing by PCR, immunoassay or culture. Because the Pathatrix™ Auto Instrument and its companion kits concentrate and isolate specific bacteria such as Salmonella, E. coli O157:H7 and Listeria from sample volumes of up to 60 ml, they support cost-saving pooling protocols, facilitate shorter sample enrichment times to reduce overall time to results, and remove PCR inhibitors that can lead to indeterminate results.

• Fully automated – simply load and push the button
• Cost effective – supports pooling protocols that save up to 90% on downstream detection costs
• Faster time to results – concentrates target organisms from 10 – 60 ml samples, so less enrichment time is required
• Fewer false positives and indeterminates – isolates specific bacteria from background flora and PCR inhibitors
• Validated – workflows validated by the AOAC Research Institute

Simple-to-Use, Automated System
The Pathatrix™ Auto Instrument automates the concentration and isolation of target bacteria from 10 – 60 ml sample volumes in only about 15 minutes. Simply add a 10-60 ml liquid sample to a sample vessel, add paramagnetic beads that are either antibody-coated or cationic depending on the target organisms of interest, and load the assembly with a filled elution tube into the instrument. Kits for the isolation of Salmonella, E. coli O157:H7, Listeria, Campylobacter and Cronobacter — which include the sample vessel, elution vessel, and corresponding beads — are available separately.

The Pathatrix™ Auto Instrument uses a proprietary technology to re-circulate the entire sample over a capture phase where the paramagnetic particles are immobilized. Target organisms are captured onto the immobilized beads, then washed and the beads eluted. The entire process takes only 15 minutes. After elution, the captured organisms, cleaned and purified, are ready for a wide variety of detection methods including PCR, Lateral Flow, ELISA and plating on selective agar.

Protocols are universal and each cartridge can be run independently, making the system convenient and easy to use. Just load, push the button to start, and walk away.

Supports Cost-saving Pooling Protocols Validated by the AOAC Research Institute
Because the Pathatrix™ Auto Instrument efficiently concentrates target bacteria from large volumes, it supports pooling protocols where up to 10 samples may be pooled after enrichment but before downstream detection. Pooling of ten post-enrichment samples reduces downstream detection costs by up to 90%. Pooling protocols validated by the AOAC Research Institute are available for Salmonella, E. coli O157:H7 and Listeria.

Reduces False-Positive and Indeterminate Results
The Pathatrix™ Auto Instrument, when used in conjunction with its associated target organism-specific kits, efficiently isolates target organisms away from background flora and potential PCR inhibitors. The result is fewer indeterminate readings due to PCR inhibition and fewer false positives. The system has been successfully used upstream from PCR with difficult matrices such as chocolate, spices, and chicken litter samples, as well as with dozens of other food sample types.

Components
The Pathatrix™ Auto Instrument includes 5 Cartridges, a Cartridge Holder, a Sample Vessel Holder and an Elution Vessel Holder. The Elution Vessel Holder includes a magnet to capture paramagnetic particles after elution.

The Pathatrix™ Auto is compatible with 100-240V (50-60 Hz) power outlets, and is supplied with three different power cords (NEMA 5-15, BS 1363 and CEE 7/16 Europlug).

To speak with a technical specialist about how the Pathatrix™ Auto Instrument can streamline your specific food testing workflow, please contact us.

사양

유형Kit

치수470 mm (H) x 418 mm (W) x 276 mm (D)

최종 제품 유형Bacteria (Intact), Viruses (Intact)

용도(장비)Pathatrix™ Auto System

고처리량 호환성Automated Protocols

보유1 to 50 samples, Up to 10 pooled samples per cartridge, 5 independent cartridges

제품라인Pathatrix

수량1 instrument

실행 시간15 min.

부피(미터법)10 to 60 mL

Unit SizeEach


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0