CacheBy
Thermo Fisher Scientific CCL14 Polyclonal Antibody, Biotin, PeproTech
원본

Thermo Fisher Scientific CCL14 Polyclonal Antibody, Biotin, PeproTech

상품 한눈에 보기

Biotin으로 표지된 Rabbit Polyclonal Anti-Human CCL14 항체로, ELISA 및 Western blot에 적합합니다. 고순도 재조합 단백질로 면역화 후 친화 크로마토그래피로 정제되었으며, 인간 시료 반응성이 있습니다. 연구용으로만 사용 가능합니다.

카탈로그번호
500-P106BT-500UG
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 03. 오후 12:11
Thermo Fisher Scientific 500-P106BT-500UG CCL14 Polyclonal Antibody, Biotin, PeproTech 500 ug pk판매 단위 pk ·
재고 확인 필요
3,831,800원VAT 포함 4,214,980원

Thermo Fisher Scientific · Thermo Fisher Scientific CCL14 Polyclonal Antibody, Biotin, PeproTech

Applications

Western Blot (WB)

  • Tested Dilution: 0.1–0.2 µg/mL

ELISA

  • Tested Dilution: 0.25–1.0 µg/mL

Product Specifications

항목 내용
Species Reactivity Human
Host/Isotype Rabbit
Class Polyclonal
Type Antibody
Immunogen E.coli-derived Recombinant Human HCC-1 (CCL14) (72 a.a.)
Conjugate Biotin
Form Lyophilized
Concentration 0.1–1.0 mg/mL
Purification Antigen affinity chromatography
Storage Buffer PBS
Contains No preservative
Storage Conditions -20°C
Shipping Conditions Ambient

Product Specific Information

AA Sequence of recombinant protein:
TESSSRGPYH PSECCFTYTT YKIPRQRIMD YYETNSQCSK PGIVFITKRG HSVCTNPSDK WVQDYIKDMK EN

Preparation:
Produced from sera of rabbits immunized with highly pure Recombinant Human HCC-1 (CCL14). Anti-Human HCC-1 (CCL14)-specific antibody was purified by affinity chromatography and then biotinylated.

Sandwich ELISA:
To detect Human HCC-1 (CCL14) by sandwich ELISA (using 100 µL/well antibody solution), a concentration of 0.25–1.0 µg/mL of this antibody is required.
This biotinylated polyclonal antibody, in conjunction with PeproTech Polyclonal Anti-Human HCC-1 (CCL14) (500-P106) as a capture antibody, allows detection of at least 0.2–0.4 ng/well of Recombinant Human HCC-1 (CCL14).

Western Blot:
To detect hHCC-1 by Western Blot analysis, this antibody can be used at a concentration of 0.1–0.2 µg/mL.
Used with compatible secondary reagents, the detection limit for Recombinant hHCC-1 is 1.5–3.0 ng/lane, under either reducing or non-reducing conditions.

Packaging:
500-P106BT-1MG will be provided as 2 × 500 µg.


Target Information

This gene, CCL14, is one of several CC cytokine genes clustered on 17q11.2.
The CC cytokines are secreted proteins characterized by two adjacent cysteines.
The cytokine encoded by this gene induces changes in intracellular calcium concentration and enzyme release in monocytes.
This gene expresses both monocistronic and bicistronic transcripts. Bicistronic transcripts include the upstream cytokine gene CCL15.
Additionally, CCL14 undergoes alternative splicing in the bicistronic transcripts; it is unknown if its monocistronic transcript is also subject to alternative splicing.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.