Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), PE, eBioscience
원본

Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), PE, eBioscience

상품 한눈에 보기

인간 HLA-A3 분자를 인식하는 단클론 항체로, Flow Cytometry에 최적화됨. PE 형광체 결합으로 565/576 nm에서 발광. 친화 크로마토그래피로 정제되었으며, 4°C 암소 보관. 연구용으로만 사용 가능.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
ADBIX 2026 전시회10/28~30 코엑스 · 사전등록 안내자세히보기
Thermo Fisher Scientific 12-5754-42 HLA-A3 Monoclonal Antibody (GAP.A3), PE, eBioscience 100 tests pk판매 단위 pk
재고 확인 필요
523,000원VAT 포함 575,300원

Thermo Fisher Scientific · Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), PE, eBioscience

Applications and Tested Dilution

  • Application: Flow Cytometry (Flow)
  • Tested Dilution: 5 µL (0.125 µg)/test
  • Publications: View 3 publications

Product Specifications

항목 내용
Species Reactivity Human
Published Species Human
Host / Isotype Mouse / IgG2a, kappa
Recommended Isotype Control Mouse IgG2a kappa Isotype Control (eBM2a), PE, eBioscience™
Class Monoclonal
Type Antibody
Clone GAP.A3
Conjugate PE
Excitation/Emission Max 565/576 nm
Form Liquid
Concentration 5 µL/Test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_2637370

Available Conjugate Formats

  • APC
  • FITC
  • NovaFluor Blue 510 / 585 / 610-70S / 660-120S / 690
  • NovaFluor Red 710 / 725
  • NovaFluor Yellow 570 / 660 / 730 / 755
  • Super Bright 436 / 600
  • Request custom conjugation

Product Specific Information

The monoclonal antibody GAP.A3 reacts with the human major histocompatibility complex (MHC) class I molecule HLA-A3, a member of the HLA-A family.
HLA-A3 has two subtypes (HLA-A3.1, HLA-A3.2) differing at amino acid positions 152 and 156.
MHC class I molecules are expressed on all nucleated cells and associate with β2 microglobulin. They present intracellular peptides to cytotoxic T lymphocytes.

HLA-A3 is expressed by 15–25% of cancer patients and can bind the tumor-associated antigen hTERT (human telomerase reverse transcriptase).

Applications Reported: Flow cytometric analysis.
Applications Tested: Pre-titrated and validated for normal human peripheral blood cells.
Use at 5 µL (0.125 µg) per test in a final volume of 100 µL (10⁵–10⁸ cells/test).

  • Excitation: 488–561 nm
  • Emission: 578 nm
  • Laser Compatibility: Blue, Green, Yellow-Green
  • Filtration: 0.2 µm post-manufacturing filtered

Target Information

HLA-A belongs to the HLA class I heavy chain paralogues, forming a heterodimer with β2-microglobulin.
These molecules present peptides from the endoplasmic reticulum lumen and are expressed in nearly all nucleated cells.
The heavy chain (~45 kDa) gene contains 8 exons encoding leader peptide, α1/α2 peptide-binding domains, α3 domain, transmembrane region, and cytoplasmic tail.

Polymorphisms within exons 2 and 3 determine peptide-binding specificity, important for bone marrow and kidney transplantation typing.
Hundreds of HLA-A alleles are known.

HLA and MHC antibodies are key tools in Immunopeptidomics, enabling identification and characterization of neoantigens via LC–MS/MS.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.