Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience
마우스 Vβ6 TCR을 인식하는 RR4-7 단클론 항체로, PerCP-eFluor 710 형광체 결합. Flow cytometry에 최적화되어 있으며 0.125 µg/test로 사용. 488 nm 레이저에 의해 여기되고 710 nm에서 방출. 4°C 암소 보관, 동결 금지.
- 카탈로그번호
- 46-5795-82
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience
Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience
Applications and Tested Dilution
- Application: Flow Cytometry (Flow)
- Tested Dilution: 0.125 µg/test
- Publications: View 4 publications
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Published Species | Mouse |
| Host / Isotype | Rat / IgG2b, kappa |
| Recommended Isotype Control | Rat IgG2b kappa Isotype Control (eB149/10H5), PerCP-eFluor™ 710, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | RR4-7 |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation / Emission Max | 482 / 708 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_11150054 |
Product Specific Information
This RR4-7 monoclonal antibody reacts with mouse V beta 6 TCR.
TCR specificity is determined by Va, Ja, Vb, Db, and Jb gene rearrangement.
The RR4-7 antibody recognizes the V beta 6 chain on T cells from mouse strains with the a (e.g., C57BR, SJL) and b haplotypes (e.g., BALB/c, C3H, DBA/1).
Strains expressing the Mls-1a antigen with MHC Class II I-E show fewer V beta 6 TCR+ T cells.
RR4-7 antibody demonstrates functional activity in vitro and in vivo.
Reported applications include flow cytometric analysis.
Tested by flow cytometric analysis of mouse splenocytes at ≤0.125 µg/test (100 µL volume).
Cell number may range from 10⁵ to 10⁸ cells/test.
Careful titration recommended for optimal performance.
PerCP-eFluor® 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.
- Emission: 710 nm
- Excitation: 488 nm (Blue Laser)
Recommended filter: 685 LP dichroic mirror and 710/40 band pass (or 695/40 BP alternative).
PerCP-eFluor® 710 conjugated antibodies are stable when samples are fixed with 2% formaldehyde overnight at 4°C.
Filtration: 0.2 µm post-manufacturing filtered.
Target Information
T cell receptors (TCR) discriminate foreign from self-peptides presented by MHC class II molecules, critical for adaptive immunity.
Self-peptide recognition is linked to autoimmune diseases, while mutant self-peptides are associated with tumors.
Superantigen engagement of TCRs can cause toxic shock syndrome.
Autoantibodies to V beta segments are found in RA and SLE patients, blocking TH1-mediated inflammation.
Most human T cells express TCR alpha-beta with CD4 or CD8 (single positive).
A small subset lacks both (double negative), increased in autoimmune and immunodeficiency disorders.
Gamma-delta T cells reside mainly in epithelia, showing less diversity and distinct antigen recognition, with antitumor and immunoregulatory roles.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.