CacheBy
Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience
원본

Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience

상품 한눈에 보기

마우스 Vβ6 TCR을 인식하는 RR4-7 단클론 항체로, PerCP-eFluor 710 형광체 결합. Flow cytometry에 최적화되어 있으며 0.125 µg/test로 사용. 488 nm 레이저에 의해 여기되고 710 nm에서 방출. 4°C 암소 보관, 동결 금지.

카탈로그번호
46-5795-82
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 02. 오전 08:58
Thermo Fisher Scientific 46-5795-82 TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
540,600원VAT 포함 594,660원

Thermo Fisher Scientific · Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience

Thermo Fisher Scientific TCR V beta 6 Monoclonal Antibody (RR4-7), PerCP-eFluor 710, eBioscience

Applications and Tested Dilution

  • Application: Flow Cytometry (Flow)
  • Tested Dilution: 0.125 µg/test
  • Publications: View 4 publications

Product Specifications

항목 내용
Species Reactivity Mouse
Published Species Mouse
Host / Isotype Rat / IgG2b, kappa
Recommended Isotype Control Rat IgG2b kappa Isotype Control (eB149/10H5), PerCP-eFluor™ 710, eBioscience™
Class Monoclonal
Type Antibody
Clone RR4-7
Conjugate PerCP-eFluor™ 710
Excitation / Emission Max 482 / 708 nm
Form Liquid
Concentration 0.2 mg/mL
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_11150054

Product Specific Information

This RR4-7 monoclonal antibody reacts with mouse V beta 6 TCR.
TCR specificity is determined by Va, Ja, Vb, Db, and Jb gene rearrangement.
The RR4-7 antibody recognizes the V beta 6 chain on T cells from mouse strains with the a (e.g., C57BR, SJL) and b haplotypes (e.g., BALB/c, C3H, DBA/1).
Strains expressing the Mls-1a antigen with MHC Class II I-E show fewer V beta 6 TCR+ T cells.

RR4-7 antibody demonstrates functional activity in vitro and in vivo.
Reported applications include flow cytometric analysis.
Tested by flow cytometric analysis of mouse splenocytes at ≤0.125 µg/test (100 µL volume).
Cell number may range from 10⁵ to 10⁸ cells/test.
Careful titration recommended for optimal performance.

PerCP-eFluor® 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.

  • Emission: 710 nm
  • Excitation: 488 nm (Blue Laser)
    Recommended filter: 685 LP dichroic mirror and 710/40 band pass (or 695/40 BP alternative).

PerCP-eFluor® 710 conjugated antibodies are stable when samples are fixed with 2% formaldehyde overnight at 4°C.
Filtration: 0.2 µm post-manufacturing filtered.


Target Information

T cell receptors (TCR) discriminate foreign from self-peptides presented by MHC class II molecules, critical for adaptive immunity.
Self-peptide recognition is linked to autoimmune diseases, while mutant self-peptides are associated with tumors.
Superantigen engagement of TCRs can cause toxic shock syndrome.
Autoantibodies to V beta segments are found in RA and SLE patients, blocking TH1-mediated inflammation.
Most human T cells express TCR alpha-beta with CD4 or CD8 (single positive).
A small subset lacks both (double negative), increased in autoimmune and immunodeficiency disorders.
Gamma-delta T cells reside mainly in epithelia, showing less diversity and distinct antigen recognition, with antitumor and immunoregulatory roles.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.