
Servicebio 8-channel Pipette
8채널 멀티채널 피펫으로 정밀한 액체 분주가 가능하며, 다양한 용량 범위와 컬러 옵션 제공. 인체공학적 디자인으로 손 피로 최소화, EN/ISO8655 기준에 따라 칼리브레이션된 고정밀 제품. 대부분의 팁과 호환되어 실험 효율 향상.
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Servicebio 8-Channel Pipette
Product Introduction
A pipette is a device used to transfer liquid quantitatively. In analytical testing research, pipettes are used to transfer small or microliter amounts of liquid.
There are 8 colors to choose from, and exclusive lucky colors can be customized.
SPIP-B10 Pipette Compatibility Chart
| Pipette | Pipette Tips Spec. | Details | Pipette Tips Cat. No. |
|---|---|---|---|
| SPIP-B10 | 10 μL | Racked (Sterile, DNase & RNase Free) | TP-10-C |
| Bagged (DNase & RNase Free) | TP-10 | ||
| 10 μL Long | Racked (Sterile, DNase & RNase Free) | TP-10P-C | |
| Bagged (DNase & RNase Free) | TP-10P | ||
| 10 μL with Filter | Filter, Racked (Sterile, DNase & RNase Free) | TP-10-C-F | |
| 10 μL Long with Filter | Filter, Racked (Sterile, DNase & RNase Free) | TP-10P-C-F |
Product Features
- Multiple volume ranges with multi-color markings; single-channel and multi-channel options.
- Lightweight spring for effortless operation.
- Equipped with Servicebio tips for excellent air tightness and accurate volume transfer.
- Compatible with most pipette tips on the market.
Product Parameter
| Product Name | Product No. | Nominal Volume | Volume Range | Increment |
|---|---|---|---|---|
| Single Channel Pipette | SPIP-2.5 | 2.5 μL | 0.1–2.5 μL | 0.05 μL |
| SPIP-10 | 10 μL | 1–10 μL | 0.1 μL | |
| SPIP-20L | 20 μL | 2–20 μL (for 10 μL and 10 μL-long tips) | 0.1 μL | |
| SPIP-20 | 20 μL | 2–20 μL (for 200 μL tips) | 0.1 μL | |
| SPIP-50 | 50 μL | 5–50 μL (for 10 μL-long tips) | 0.5 μL | |
| SPIP-100 | 100 μL | 10–100 μL | 1 μL | |
| SPIP-200 | 200 μL | 20–200 μL | 1 μL | |
| SPIP-1000 | 1000 μL | 100–1000 μL | 5 μL | |
| SPIP-5000 | 5000 μL | 1000–5000 μL | 50 μL | |
| SPIP-10000 | 10 mL | 1–10 mL | 100 μL | |
| 8-Channel Pipette | SPIP-B10 | 10 μL | 1–10 μL | 0.1 μL |
| SPIP-B20L | 20 μL | 2–20 μL | 0.1 μL | |
| SPIP-B50 | 50 μL | 5–50 μL | 0.5 μL | |
| SPIP-B100 | 100 μL | 10–100 μL | 1 μL | |
| SPIP-B300 | 300 μL | 50–300 μL | 1 μL | |
| SPIP-B1000 | 1000 μL | 100–1000 μL | 5 μL |
Additional Product Features
- Single channel: 0.1–2.5 μL to 1–10 mL; multi-color range markers; 10 sizes optional.
- Multi-channel: 1–10 μL to 100–1000 μL; 6 sizes optional.
- Lightweight ergonomic design reduces hand fatigue.
- Large digital display for clear volume adjustment.
- High-strength, corrosion-resistant materials; compatible with alcohol and UV sterilization.
- Color-coded handles for easy identification.
- Calibrated according to EN/ISO8655 standard for precision and reliability.
Pipette Structure (from image OCR)
- Push Rod
- Push Button / Volume Turn Button (Top Cap)
- Handle Grippy
- Tip Ejection Button
- Handle
- Volume Display
- Tip Ejection Part
- Pipe Tip
Label markings: “300”, “SCINICBIO”, “SERIE 3000”, numbered 1–8 for channels.
Pipette Operation
Forward Technique (low-density liquids):
- Press the push button to the first STOP.
- Slowly release to the ready position to aspirate liquid.
- Deliver by pressing to the first STOP, then to the second STOP to empty.
- Release button to ready position; change tip if needed.
Reverse Technique (high-viscosity or volatile liquids):
- Depress button to the second STOP for aspiration, then release slowly.
- Press to the first STOP to discharge preset volume.
- Discard remaining liquid with the tip.
Position Labels (from image OCR):
Ready Position → First STOP → Second STOP
Calibration and Adjustment
Use the Service Tool to adjust volume:
- Turn clockwise to increase, counterclockwise to decrease.
- Calibrate 1–2 times per year depending on usage frequency.
Notes from image OCR:
Mantissa (Increment) refers to product data sheet.
Storage and Transportation
Store and transport at room temperature.
Notice
- Ensure pipette and tips are at the same temperature before use.
- Keep pipette upright during aspiration; immerse tip 2–3 mm below liquid surface.
- Avoid turning pipette upside down when filled.
- Use within specified volume range.
- Apply maintenance oil to sealing ring if unused for long periods.
- Seek professional technician for disassembly or repair.
Pipette and Tip Adaptation Table (from image OCR)
| Cat. No. | SPP-2.5 | SPP-10 | SPP-20 | SPP-20L | SPP-50 | SPP-100 | SPP-200 | SPP-1000 | SPP-5000 | SPP-10000 | SPP-810 | SPP-820L | SPP-850 | SPP-830 | SPP-830L | SPP-81000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette |
| Spec. | 0.1–2.5 μL | 0.5–10 μL | 2–20 μL | 2–20 μL (Long tips) | 5–50 μL | 10–100 μL | 20–200 μL | 100–1000 μL | 0.5–5000 μL | 1–10 mL | 0.5–10 μL (8 tips) | 2–20 μL (Long tips, 8 tips) | 5–50 μL (8 tips) | 5–300 μL (8 tips) | 5–300 μL (Long tips, 8 tips) | 10–1000 μL (8 tips) |
Tip Compatibility Summary
“√” = Compatible
“Unable to aspirate XX μL” = Not compatible for that volume
“Able to aspirate XX μL” = Compatible for specific volume
Related Products
Servicebio provides FDA & CE approved laboratory instruments and consumables.
제품 이미지





배송/결제/교환/반품 안내
배송 정보
| 기본 배송비 |
| 교환/반품 배송비 |
|
|---|---|---|---|
| 착불 배송비 |
| ||
| 교환/반품 배송비 |
| ||
결제 및 환불 안내
| 결제수단 |
|
|---|---|
| 취소 |
|
| 반품 |
|
| 환급 |
|
교환 및 반품 접수
| 교환 및 반품 접수 기한 |
|
|---|---|
| 교환 및 반품 접수가 가능한 경우 |
|
| 교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
| 교환 절차 |
|
|---|---|
| 반품 절차 |
|




