Thermo Fisher Scientific GP6 Monoclonal Antibody (HY101), eFluor 660, eBioscience
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
50-9813-42 | - | Thermo Fisher Scientific 50-9813-42 GP6 Monoclonal Antibody (HY101), eFluor 660, eBioscience 100 tests pk | 재고문의 | pk | 383,000원 | - | 421,300원 | |
50-9813-41 | - | Thermo Fisher Scientific 50-9813-41 GP6 Monoclonal Antibody (HY101), eFluor 660, eBioscience 25 tests pk | 재고문의 | pk | 0원 | - | 0원 |
다른 상품 둘러보기
Applications
Tested Dilution
Publications
Flow Cytometry (Flow)
5 µL (0.25 µg)/test
View 1 publication 1 publication
Product Specifications
Published species
Human
Host/Isotype
Mouse / IgG1, kappa
Recommended Isotype Control
Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), eFluor™ 660, eBioscience™
Class
Monoclonal
Type
Antibody
Clone
HY101
Conjugate
eFluor™ 660 eFluor™ 660 eFluor™ 660
View additional formats
Excitation/Emission Max
651/668 nm View spectra
Form
Liquid
Concentration
5 µL/Test
Storage conditions
4° C, store in dark, DO NOT FREEZE!
Shipping conditions
Wet ice
RRID
AB_11218081
Product Specific Information
Description: The HY101 monoclonal antibody reacts with the glycoprotein VI (GPVI), a 62-kDa type-I transmembrane glycoprotein that is expressed on mature megakaryotes and platelets. GPVI associates with the Fc receptor (FcR) gamma-chain to form a high affinity receptor for collagen. GPVI has also been reported to bind convulxin (Cvx). Phosphorylation of the ITAMs present on the FcR gamma-chain leads to recruitment of Src family kinases and activation of downstream signal transduction. GPVI has been reported to play a critical role in platelet activation and aggregation.
Applications Reported: This HY101 antibody has been reported for use in flow cytometric analysis.
Applications Tested: This HY101 antibody has been pre-titrated and tested by flow cytometric analysis of normal human platelets. This can be used at 5 µL (0.25 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.
eFluor™ 660 is a replacement for Alexa Fluor™ 647. eFluor™ 660 emits at 659 nm and is excited with the red laser (633 nm). Please make sure that your instrument is capable of detecting this fluorochome.
Excitation: 633-647 nm; Emission: 668 nm; Laser: Red Laser.
Filtration: 0.2 µm post-manufacturing filtered.
Target Information
Glycoprotein VI (GP6) is a 58-kD platelet membrane glycoprotein that plays a crucial role in the collagen-induced activation and aggregation of platelets. Upon injury to the vessel wall and subsequent damage to the endothelial lining, exposure of the subendothelial matrix to blood flow results in deposition of platelets. Collagen fibers are the most thrombogenic macromolecular components of the extracellular matrix, with collagen types I, III, and VI being the major forms found in blood vessels. Platelet interaction with collagen occurs as a 2-step procedure: (1) the initial adhesion to collagen is followed by (2) an activation step leading to platelet secretion, recruitment of additional platelets, and aggregation. In physiologic conditions, the resulting platelet plug is the initial hemostatic event limiting blood loss. However, exposure of collagen after rupture of atherosclerotic plaques is a major stimulus of thrombus formation associated with myocardial infarction or stroke.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|