CacheBy
Thermo Fisher Scientific Angiotensin I Converting Enzyme (ACE)/CD143 Recombinant Rabbit Monoclonal Antibody (ACE/7004R)
원본

Thermo Fisher Scientific Angiotensin I Converting Enzyme (ACE)/CD143 Recombinant Rabbit Monoclonal Antibody (ACE/7004R)

상품 한눈에 보기

인간 ACE/CD143 단백질을 인식하는 재조합 토끼 단클론 항체. ELISA 등 면역분석에 적합하며, Protein A/G 정제 및 PBS 버퍼에 보존. 4°C에서 보관, 동결 금지. 연구용으로만 사용 가능.

카탈로그번호
1636-RBM9-Px (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 10:19
Thermo Fisher Scientific 1636-RBM9-P1 Angiotensin I Converting Enzyme (ACE)/CD143 Recombinant Rabbit Monoclonal Antibody (ACE/7004R) 100 ug pk판매 단위 pk ·
재고 확인 필요
1,063,800원VAT 포함 1,170,180원
Thermo Fisher Scientific 1636-RBM9-P0 Angiotensin I Converting Enzyme (ACE)/CD143 Recombinant Rabbit Monoclonal Antibody (ACE/7004R) 20 ug pk판매 단위 pk ·
재고 확인 필요
452,600원VAT 포함 497,860원

Thermo Fisher Scientific · Thermo Fisher Scientific Angiotensin I Converting Enzyme (ACE)/CD143 Recombinant Rabbit Monoclonal Antibody (ACE/7004R)

Applications

  • ELISA (ELISA): Assay-dependent

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Rabbit / IgG
Expression System HEK293 cells
Class Recombinant Monoclonal
Type Antibody
Clone ACE/7004R
Immunogen Recombinant fragment (around aa 652-788) of human ACE/CD143 protein
Conjugate Unconjugated
Form Liquid
Concentration 200 µg/mL
Purification Protein A/G
Storage Buffer PBS, pH 7.4, with 0.05% BSA
Contains 0.05% sodium azide
Storage Conditions 4°C, do not freeze
Shipping Conditions Ambient (domestic); Wet ice (international)

Target Information

This gene encodes an enzyme that catalyzes the conversion of angiotensin I into the physiologically active peptide angiotensin II. Angiotensin II is a potent vasopressor and aldosterone-stimulating peptide that regulates blood pressure and fluid-electrolyte balance. This enzyme plays a key role in the renin-angiotensin system. Variations in this gene, such as the presence or absence of a 287 bp Alu repeat element, have been associated with circulating enzyme levels and cardiovascular pathophysiologies. Two main alternatively spliced variants encode the somatic and testicular isozymes, both active forms. Additional splice variants have been identified, but their full-length sequences remain undetermined.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.