VELP CN 802 Carbon Nitrogen Elemental Analyzer

상품 옵션 정보
카탈로그 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
F30800090VELP F30800090 CN 802, Carbon/Nitrogen Elemental Analyzer, 탄소/질소 원소분석기 set재고문의set0-0

Fast and simultaneous Carbon Nitrogen analyses

The CN 802 a robust and flexible combustion analyzer, that works in accordance with official reference methods for the determination of carbon and nitrogen in many industrial sectors such as agriculture, environmental, food & feed and chemical.

The CN 802 is powered by the CNSoftTM software and produces unsupervised, simultaneous results in 5 minutes, totally unsupervised of:

  • Total Carbon - TC
  • Total Organic and Inorganic Carbon (after acidification) - TOC, TIC
  • Total Nitrogen - TN
  • C/N Ratio

The CN 802 is a safe analyzer that does not require aggressive chemicals or time-consuming analysis steps. Just prepare your sample and walk away!

VELPElemental-analyzersNDA06-210368-212028.jpg

Versatile and sensitive

With the CN 802 you can load different matrix of solid, semi-solid and liquid samples at the same time.

Carbon detection from ppm - 150 mgC, the lowest Nitrogen LOD in the market of *0.001 mgN with *Helium and the RSD lower than 0.5% (EDTA) assure you high precision results and excellent reproducibility.

VELP CN 802 elemental analyzer is designed to work 24/7, 365 days a year with fast and easy routine maintenance.

The autosampler is supplied with a disc of 30 positions and can be expanded to accommodate up to 117 samples.

Cn802VELP800-212032.jpg

Efficiency for your lab

CN 802 analyzes samples of up to 1 g and reduces operating costs thanks to VELP engineering and genuine consumables with extended lifetime. Furthermore, CN 802 allows cost reduction related to Helium availability thanks to the seamless choice of Argon.

  • The selective Non-Dispersive Infrared NDIR detector is maintenance-free and reads only Carbon content;
  • The CN 802 LoGasTM TCD works with no reference gas ensuring accuracy and precision;
  • Very low oxygen consumption thanks to optimized combustion;
  • The maintenance-free DriStepTM water trap is a physical trap that removes 99% of water, reducing the cost of chemicals;
  • CN 802 is easy to install and extremely compact saving valuable bench space in your lab

VELP TEMS technology drastically reduces wastes compared to wet chemistry N/protein determination methods.

Cn802processVELP800-212038-212039.jpg

CN 802 Working Process

The sample is purged with carrier and drops down into the combustion reactor where it is converted in its elemental compounds at a high temperature (>1000°C).

Water separation is performed in 2 steps. The first is the maintenance-free physical trap DriStep™ (WT1) strategically placed after combustion. The second is a chemical trap (WT2), ensuring the complete elimination of residual 1% of water.

The combination of high temperature and the exclusive VcopperTM reduces nitrogen dioxide to molecular nitrogen inside the reduction furnace.

The VELP NDIR detector precisely detects Carbon concentration with an excellent limit of detection.

The auto-regenerative CO2 absorbers trap carbon dioxide in order for the exclusive TCD (Thermal Conductivity Detector) to detect the Nitrogen content.

CNSoft800-212046-212047.jpg

Intuitive interactions with CNSoft™

The CNSoft™ software is the powerful VELP solution that controls and operates the CN 802 analyzer.

The CNSoft™ comes with a user-friendly interface that displays all relevant information at a glance: results, database and instrument conditions.

It is possible to choose from a rich library of pre-installed methods and create customized ones. An easy calibration curve creation for Carbon and Nitrogen allows for testing of any sample matrix with no memory effect.

Run the complete Leak Test and choose whether to run it on the whole circuit or targeted by zone, after replacing a consumable for example.

VELPElemental-analyzersNDA05-209978-212050-212051.jpg

Adding value to automation via the cloud

CN 802 thanks to its connectivity to VELP Ermes allows you to reduce routine operations thanks to the real-time monitoring of your elemental analyzer wherever you are, at any time.

CN 802 is designed for continuous work with fully automated processes, VELP Ermes allows you to manage multiple instruments, consumables, workflows and to drastically reduce diagnostic time to ensure a superior level of service with maximum data security and protection of your data.

Immediate notifications and alerts will allow you to be always informed about the status of your analysis and thanks to the remote interruption you will have total control of your processes ensuring maximum security.

Access the database of your instrument in total security through the VELP Ermes platform and work with your colleagues creating and sharing reports from PC, smartphone and tablet.

TECHNICAL DATA

METHOD OF ANALYSIS: Cabon/Nitrogen determination according to combustion method
DURATION OF ANALYSIS: 4/5 minutes
DETECTOR: N= TCD (Thermal Conductivity Detector)
C= NDIR Detector (Non Dispersive Infrared)
SAMPLE WEIGHT: Up to 1g
AUTOSAMPLER CAPACITY: up to 4 discs, 30 positions each (up to 117 samples)
REPRODUCIBILITY (RSD): < 0.5% for EDTA standards approx. 100 mg
RECOVERY: > 99.5%
DETECTION RANGE C: ppm - 150 mgC
DETECTION RANGE N: ppm - 200 mgN
CARRIER GAS: Helium or Argon
NITROGEN DETECTION LIMIT (ABSOLUTE VALUES): 0.001 mg N, with Helium
0.01 mg N, with Argon
CARBON DETECTION LIMIT (ABSOLUTE VALUES): 0.01 mgC
COMBUSTION TEMPERATURE: 1030 °C / 1886°F
CARRIER GAS (HE/AR): purity 99.999% (grade 5.0)
OXYGEN (O2): purity 99.999% (grade 5.0)
CARRIER GAS (HE/AR) PRESSURE: 2 bar
OXYGEN (O2) PRESSURE: 2 bar
CONNECTIVITY Cloud via LAN or Wi-Fi
INTERFACES: USB; RS232
POWER: 1400 W
POWER SUPPLY: 230 V / 50 - 60 Hz
WEIGHT: 54 kg / 119 lb
DIMENSIONS (WXHXD): 655x510x410 mm (H 690 mm with autosampler)
25.8x20.1x16.1 in (H 27.0 in with autosampler)

Brochures & Leaflets

VELP Scientifica invites you to download brochures and leaflets in order to explore our premium quality solutions and to have all the major key arguments, features and specifications of a product in your hands, in any place, and at any time.

CN 802 Carbon Nitrogen Analyzer Brochure [EN]
CN 802 - How to connect to VELP Ermes
Analytical Instruments - Line Brochure [EN]
Product Portfolio - Brochure [EN]

Application notes

Choose among a comprehensive library of Application Notes / White Papers and learn more on how to optimize the performance of your VELP instruments. These documents offer typical analyses of well-known samples, together with official references and suggestions, to make you an expert!

Carbon and Nitrogen determination in liquid fertilizers
CN 802 - TC and TOC determination in Sludge
CN 802 - Total Carbon and Nitrogen Determination in Soil
Total Carbon, Nitrogen and TOC Determination in reference soils and sediment samples

Certifications

Our compliance to statutory rules and regulations worldwide.
With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the European Directive on Safety.
The Certification Body (CB) Certificate is an international program created by the IECEE for the acceptance of product safety test results among participating laboratories and certification organizations around the world.
The cNEMKOus mark ensures this product is designed and manufactured in compliance with the International Directive on Safety IEC/EN 61010-1. The cNEMKOus mark has the same legal status as any other NRTL/SCC accredited marks, for U.S. and Canada.

Total Carbon, Nitrogen and TOC Determination in reference soils and sediment samples


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드 결제 (결제링크 문자+이메일 전송)
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0