
Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), eBioscience
Armenian hamster 유래 IgG 단클론 아이소타입 컨트롤 항체로, Flow Cytometry, IHC, ICC 등 다양한 면역분석에 사용 가능. 비특이적 결합 평가용 음성 대조로 최적. 0.5 mg/mL 액상, PBS buffer, 4°C 보관.
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Applications and Tested Dilution
| Application | Tested Dilution |
|---|---|
| Immunohistochemistry (Paraffin) (IHC (P)) | Assay-Dependent |
| Immunocytochemistry (ICC/IF) | Assay-Dependent |
| Flow Cytometry (Flow) | Assay-Dependent |
| Control (Ctrl) | Assay-Dependent |
Product Specifications
| Specification | Description |
|---|---|
| Host/Isotype | Armenian hamster / IgG |
| Class | Monoclonal |
| Type | Isotype Control |
| Clone | eBio299Arm |
| Conjugate | Unconjugated |
| Form | Liquid |
| Concentration | 0.5 mg/mL |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C |
| Shipping conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_470128 |
Available Conjugated Formats
- Alexa Fluor 488
- Alexa Fluor 532
- Alexa Fluor 660
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV 395, 496, 563, 615, 661, 737, 805
- Brilliant Violet 421, 480, 605, 650, 711, 786
- eFluor 450, 506, 615, 660
- FITC
- Functional Grade
- PE, PE-Cyanine5, PE-Cyanine5.5, PE-Cyanine7, PE-eFluor 610
- PerCP-Cyanine5.5, PerCP-eFluor 710
- Super Bright 436, 600, 645, 702, 780
- Request custom conjugation available
Product Specific Information
Description:
The eBio299Arm monoclonal antibody is useful as an isotype control immunoglobulin.
Applications Reported:
This antibody has been reported for use in flow cytometric analysis, immunohistochemical staining, and immunocytochemistry.
Applications Tested:
Tested by flow cytometric analysis of mouse splenocytes and normal human peripheral blood.
Use isotype control at the same concentration as the experimental antibody.
Purity: Greater than 90%, as determined by SDS-PAGE.
Aggregation: Less than 10%, as determined by HPLC.
Filtration: 0.2 µm post-manufacturing filtered.
Target Information
The isotype of a primary antibody and the application it is used in can result in background staining.
Primary antibody background noise can be caused by binding to Fc receptors, non-specific interactions, or cell autofluorescence.
Isotype control antibodies act as negative controls to differentiate non-specific background signal from specific antibody signal.
They are most commonly used in flow cytometry but also useful in ChIP, immunohistochemistry, and gel shift assays.
Isotype controls should match the primary antibody species and isotype, and when using directly labeled antibodies, the control should have the same conjugate label.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific EOMES Monoclonal Antibody (21Mags8), eBioscience
202,400원

Thermo Fisher Scientific
Thermo Fisher Scientific EOMES Monoclonal Antibody (WD1928), eBioscience
231,700원

Thermo Fisher Scientific
Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), eBioscience
92,900원

Thermo Fisher Scientific
Thermo Fisher Scientific Syrian Hamster IgG Isotype Control, eBioscience
92,900원

Thermo Fisher Scientific
Thermo Fisher Scientific Laboratory Blenders Two Speeds (145097P)
1,605,300원
배송/결제/교환/반품 안내
배송 정보
| 기본 배송비 |
| 교환/반품 배송비 |
|
|---|---|---|---|
| 착불 배송비 |
| ||
| 교환/반품 배송비 |
| ||
결제 및 환불 안내
| 결제수단 |
|
|---|---|
| 취소 |
|
| 반품 |
|
| 환급 |
|
교환 및 반품 접수
| 교환 및 반품 접수 기한 |
|
|---|---|
| 교환 및 반품 접수가 가능한 경우 |
|
| 교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
| 교환 절차 |
|
|---|---|
| 반품 절차 |
|