
Thermo Fisher Scientific CD134 (OX40) Monoclonal Antibody (OX-86), PerCP-eFluor 710, eBioscience
마우스 CD134(OX40) 인식 라트 단클론 항체로, PerCP-eFluor 710 형광 표지. 활성화된 T세포 분석에 적합하며, Flow Cytometry에 최적화. 488 nm 청색 레이저로 여기, 710 nm 방출. 연구용으로만 사용.
- 카탈로그번호
- 46-1341-8x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD134 (OX40) Monoclonal Antibody (OX-86), PerCP-eFluor 710, eBioscience
Thermo Fisher Scientific CD134 (OX40) Monoclonal Antibody (OX-86), PerCP-eFluor 710, eBioscience
Applications and Tested Dilution
- Immunohistochemistry (Frozen) (IHC(F)): Not tested
View 1 publication - Flow Cytometry (Flow): 0.25 µg/test
View 4 publications
Product Specifications
| 항목 | 내용 |
|---|---|
| Published Species | Mouse |
| Host / Isotype | Rat / IgG1, kappa |
| Recommended Isotype Control | Rat IgG1 kappa Isotype Control (eBRG1), PerCP-eFluor™ 710, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | OX-86 |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation / Emission Max | 482 / 708 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Wet ice |
| RRID | AB_2573711 |
Available Formats
- Unconjugated
- APC
- Functional Grade
- PE
- PE-Cyanine7
- Super Bright 436
- Super Bright 780
- Custom conjugation available
Product Specific Information
Description:
The OX-86 monoclonal antibody reacts with mouse CD134 (OX40), a 50 kDa type I membrane glycoprotein expressed on activated mouse T lymphocytes. Mouse CD134 is expressed by both activated CD4+ and CD8+ T cells. The CD134–CD252 (OX40 ligand) interaction regulates humoral responses, T cell expansion and survival, memory T cell pool size, and tolerance in CD4+ compartments.
Applications Reported:
Suitable for flow cytometric analysis.
Applications Tested:
Validated for flow cytometric analysis of stimulated mouse splenocytes. Recommended ≤0.25 µg per test (100 µL final volume). Optimal antibody titration advised.
Fluorophore Characteristics:
PerCP-eFluor® 710 emits at 710 nm and is excited with the blue laser (488 nm). Recommended filter: 710/50 bandpass (695/40 acceptable alternative). Verify instrument compatibility.
Fixation:
Samples can be stored in IC Fixation Buffer (Product #00-8222-49) or 1-step Fix/Lyse Solution (Product #00-5333-54) for up to 3 days at 4°C in the dark with minimal impact on brightness and FRET efficiency.
Filtration:
0.2 µm post-manufacturing filtered.
Target Information
OX40 is a receptor expressed on T cells that promotes proliferation and survival upon activation, enhancing immune responses against cancer and infections. OX40 agonists show promise as immunotherapy agents, potentially improving outcomes in cancer, autoimmune diseases, and allergies.
For Research Use Only. Not for use in diagnostic procedures.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
