CacheBy
Thermo Fisher Scientific CarrierMax SMN1/SMN2 Reagent Kit
AI 생성AI가 생성·보정한 이미지예요. AI는 실수할 수 있으니 실제 제품과 다를 수 있어요.
1 / 2

Thermo Fisher Scientific CarrierMax SMN1/SMN2 Reagent Kit

상품 한눈에 보기

SMN1 및 SMN2 유전자 엑손 7 결실을 검출하는 다중 PCR 기반 시약 키트. SMA 캐리어 스크리닝 연구용으로 설계되어 2+0 silent carrier 변이도 판별 가능. GeneMapper 및 CarrierMax 소프트웨어와 연동해 데이터 분석 및 분류를 간소화.

카탈로그번호
952363
카테고리
PCR Reagents
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 03. 오전 12:04
Thermo Fisher Scientific 952363 CarrierMax SMN1/SMN2 Reagent Kit Each pk판매 단위 pk · 1~2일 내 출고
재고 1개
3,213,100원VAT 포함 3,534,410원

Thermo Fisher Scientific · Thermo Fisher Scientific CarrierMax SMN1/SMN2 Reagent Kit

Applied Biosystems™ CarrierMax™ SMN1/SMN2 Reagent Kit

The CarrierMax SMN1/SMN2 Reagent Kit utilizes multiplex PCR amplification of genomic DNA and capillary electrophoresis to detect deletions in exon 7 of the Survival of Motor Neuron 1 (SMN1) gene that result in truncated SMN protein. Additionally, the kit detects two variants associated with the silent carrier (2+0) haplotype.

Results are processed with GeneMapper Software and CarrierMax Software to consolidate data and simplify carrier classifications in spinal muscular atrophy (SMA) carrier screening research.

Key Features

  • Accurately and consistently detect Exon 7 copy number states (0, 1, or ≥2) for both SMN1 and SMN2
  • Determine if SMN1 to SMN2 Exon 7 gene conversion has occurred
  • Detect haplotype variants associated with SMA silent (2+0) carrier status
  • Perform fragment analysis on Applied Biosystems 3500/3500xL or SeqStudio Genetic Analyzer
  • Analyze and report carrier classification easily using GeneMapper and CarrierMax Software

Research Background

SMA associated with loss of SMN1 is a leading cause of neurodegenerative disorders and a critical target for carrier screening.
Approximately 95% of SMN1 losses are due to complete gene deletions or point mutations in Exon 7 that lead to splice variants and less functional SMN2 transcripts.
In some cases, recombination results in two SMN1 genes on one chromosome (2+0), which conventional methods may miss.
The CarrierMax kit enables rapid and accurate determination of SMN1 Exon 7 copy number and potential 2+0 carrier status through haplotype assessment.

How to Use

The kit includes reagents for 50 samples for SMN1 carrier screening research using SeqStudio or Applied Biosystems 3500 genetic analyzers.
The workflow involves:

  1. Preparation of high-quality DNA (e.g., whole blood)
  2. Dual PCR cycling reactions (~2 hours)
  3. Capillary electrophoresis run (~1 hour)
  4. Data analysis (~10 minutes)

Downloads

Quality of Performance

  • Analytical sensitivity and specificity: >99% (Coriell control standards)
  • Accuracy in carrier classification: >99%
  • Proven reproducibility across experiments, labs, and systems
  • Suitable for Expanded Carrier Screening research applications

제품 사양

항목 내용
형식 Kit
용도(장비) Applied Biosystems 3500 Genetic Analyzer, 3500 XL Genetic Analyzer, SeqStudio Genetic Analyzer
용도(애플리케이션) Genotyping Using Fragment Analysis for Carrier Screening Research
라벨 또는 염료 6-FAM, HEX, ROX
제품 유형 SMN1/SMN2 Reagent Kit
수량 50 Samples
타겟 SMN1, SMN2
Unit Size Each

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0