Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Red 700, eBioscience
인간 CD4 항원 인식용 SK3 단클론 항체로, NovaFluor Red 700 형광체 결합형입니다. Flow Cytometry 분석에 최적화되어 있으며, HIV 수용체 연구 및 T helper 세포 표지에 활용됩니다. CellBlox Plus Blocking Buffer 포함, 고감도 형광 신호 제공.
- 카탈로그번호
- H001T0xxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Red 700, eBioscience
Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Red 700
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.1 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host/Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | SK3 (SK-3) |
| Conjugate | NovaFluor™ Red 700 |
| Excitation/Emission Max | 637 / 701 nm |
| Form | Liquid |
| Concentration | 2 µL/Test |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3097866 (AB_2896367) |
Additional Formats Available
- Alexa Fluor 532
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Brilliant UV 395 ~ 805
- Brilliant Violet 421, 605
- eFluor 450
- FITC
- NovaFluor Blue Series (510~800)
- NovaFluor Red Series (660~755)
- NovaFluor Violet Series (690~800)
- NovaFluor Yellow Series (570~810)
- PE, PE-Cyanine5.5, PE-Cyanine7, PE-eFluor 610
- PerCP-eFluor 710
- Super Bright Series (436~780)
- Custom conjugation available
Product Specific Information
The SK3 monoclonal antibody reacts with human CD4, a 59-kDa cell surface receptor expressed by thymocytes, mature T helper cells, and at low levels on monocytes. CD4 serves as a receptor for HIV, and SK3 blocks HIV binding and mixed lymphocyte reaction. SK3 and RPA-T4 recognize distinct epitopes.
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and validated for flow cytometry using normal human peripheral blood cells. Recommended use: 5 µL (0.1 µg) per test (100 µL total volume, 10⁵–10⁸ cells/test).
Usage Notes:
- NovaFluor dyes are incompatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assays.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining.
- Add 5 µL per sample to antibody cocktails before combining with cells.
- For single-color controls: use 5 µL per 100 µL of cell sample (10³–10⁸ cells).
NovaFluor conjugates utilize Phiton technology with engineered fluorescent signatures optimized for minimal spillover and spread.
Excitation: 639 nm
Emission: 700 nm
Laser: 633–640 nm (Red)
Target Information
CD4 antigen recognizes MHC class II molecules and acts as a co-receptor for HIV. Expressed primarily on T helper cells, as well as monocytes, macrophages, and dendritic cells. Tissue expression includes thymus, lymph nodes, tonsils, spleen, and regions of brain and gut. CD4 is involved in T-cell activation via association with the T-cell receptor and Lck kinase, and may mediate neuronal damage in immune-related CNS diseases. Multiple splice variants are known (RefSeq, July 2017).