Thermo Fisher Scientific HLA-ABC Monoclonal Antibody (W6/32), NovaFluor Red 725, eBioscience
인간 HLA-A, B, C 항원을 인식하는 W6/32 단클론 항체로, NovaFluor Red 725 형광체가 결합된 제품입니다. Flow Cytometry용으로 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 사용 시 최적의 형광 신호를 제공합니다. 636/727 nm의 Excitation/Emission 특성을 가집니다.
- 카탈로그번호
- H020T0xxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific HLA-ABC Monoclonal Antibody (W6/32), NovaFluor Red 725, eBioscience
Thermo Fisher Scientific HLA-ABC Monoclonal Antibody (W6/32), NovaFluor Red 725, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.6 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG2a, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | W6/32 |
| Conjugate | NovaFluor™ Red 725 |
| Excitation / Emission Max | 636 / 727 nm |
| Form | Liquid |
| Concentration | 0.6 µg/Test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098241 (AB_2925854) |
Additional Formats
- Unconjugated
- Alexa Fluor 700
- APC
- Biotin
- Brilliant UV 395 / 615 / 737
- Brilliant Violet 650 / 786
- FITC
- Functional Grade
- NovaFluor Blue 510 / 610-70S / 660-120S / 690
- NovaFluor Red 710 / 755
- NovaFluor Yellow 590 / 660 / 755
- PE / PE-Cyanine5 / PE-Cyanine7
- PerCP-eFluor 710
- Super Bright 436 / 600 / 702
- Request custom conjugation available
Product Specific Information
The W6/32 monoclonal antibody reacts with human MHC class I antigens (HLA-A, B, C). These antigens, associated with beta2-microglobulin, are expressed on all nucleated cells and play a key role in cell-mediated immune response and tumor surveillance.
W6/32 mAb recognizes a non-polymorphic epitope shared among HLA-A, B, and C loci and immunoprecipitates both 43 kDa and 11–12 kDa chains. Cross-reactivity is observed in baboon, rhesus, and cynomolgus monkey.
Each product includes:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested on human peripheral blood cells at 5 µL (0.6 µg) per test (100 µL final volume). Cell number range: 10⁵–10⁸ cells/test.
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability analysis.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining.
- Add 5 µL per sample to antibody cocktails prior to combining with cells.
- For single-color controls, use 5 µL per 100 µL cell sample (10³–10⁸ cells).
Technology: NovaFluor conjugates utilize Phiton™ technology with engineered fluorescent signatures optimized for minimal spillover and spread.
Excitation: 636 nm
Emission: 727 nm
Laser: 633–640 nm (Red)
Target Information
HLA-class I MHC antigens are membrane glycoproteins expressed on nucleated cells, associated with beta2-microglobulin. They present foreign determinants recognized by cytotoxic T cells, essential for antiviral and antitumor defense.
HLA and MHC antibodies are vital in immunopeptidomics, aiding neoantigen identification and characterization via LC-MS/MS analysis.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.