CacheBy
Thermo Fisher Scientific CD195 (CCR5) Monoclonal Antibody (eBioT21/8 (T21/8)), PE, eBioscience
원본

Thermo Fisher Scientific CD195 (CCR5) Monoclonal Antibody (eBioT21/8 (T21/8)), PE, eBioscience

상품 한눈에 보기

인간 CCR5(CD195)를 인식하는 PE-conjugated mouse monoclonal antibody로, Flow Cytometry에 최적화됨. HIV 연구 및 면역세포 분석용. 5 µL/test로 사용하며, 4°C 암소 보관. Affinity chromatography로 정제됨.

카탈로그번호
12-1957-42
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 01. 오후 06:24
Thermo Fisher Scientific 12-1957-42 CD195 (CCR5) Monoclonal Antibody (eBioT21/8 (T21/8)), PE, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
525,000원VAT 포함 577,500원

Thermo Fisher Scientific · Thermo Fisher Scientific CD195 (CCR5) Monoclonal Antibody (eBioT21/8 (T21/8)), PE, eBioscience

Applications

  • Flow Cytometry (Flow): 5 µL (0.125 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Mouse / IgG1, kappa
Recommended Isotype Control Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), PE, eBioscience™
Class Monoclonal
Type Antibody
Clone eBioT21/8 (T21/8)
Conjugate PE
Excitation / Emission Max 565 / 576 nm
Form Liquid
Concentration 5 µL/Test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_10853667

Additional Formats

Product Specific Information

Description:
The eBioT21/8 monoclonal antibody reacts with the amino terminus of human CCR5 (CD195), an approximately 45 kDa member of the G protein-coupled receptor (GPCR) superfamily that binds chemokines including MIP-1α, MIP-1β, and RANTES. CCR5 is expressed on resting T cells with a memory/effector phenotype, monocytes, macrophages, and immature dendritic cells. It functions as a receptor directing lymphocyte chemotaxis and serves as the primary co-receptor for macrophage-tropic HIV-1, binding through gp120. Binding of this antibody may vary among donors and can be affected by staining conditions.

Applications Reported:
Reported for use in flow cytometric analysis.

Applications Tested:
Pre-titrated and validated by flow cytometry on normal human peripheral blood cells. Recommended staining at room temperature or 37°C for 1 hour in Flow Cytometry Staining Buffer (Product # 00-4222-57).

  • Use at 5 µL (0.125 µg) per test
  • A test = antibody amount to stain cells in 100 µL final volume
  • Cell number: 10⁵–10⁸ cells/test (empirically determined)

Optical Properties:
Excitation: 488–561 nm
Emission: 578 nm
Compatible Lasers: Blue, Green, Yellow-Green
Filtration: 0.2 µm post-manufacturing filtered

Target Information

HIV and related viruses require co-receptors in addition to CD4 to infect target cells. CCR5, a chemokine receptor, acts as a principal co-receptor for macrophage- and dual-tropic HIV-1 strains, facilitating viral fusion and entry into human white blood cells. CCR5 is essential for infection by HIV-1, HIV-2, and SIV. Its ligands—RANTES, MIP-1α, and MIP-1β—can prevent M-tropic HIV-1 infection. CCR5 mRNA is expressed in lymphoid organs and monocytes, and its amino-terminal domain and extracellular loops serve as HIV binding sites.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.