demo-button-400x100.png


Catalogue
Anoxomat® III Anaerobic Jar System


Anoxomat® III Anaerobic Jar System

240260-advanced-anoxomat.png

Exact, repeatable environments for bacterial growth.

  • Anaerobic, microaerophilic, & capnophilic environments in under 5 minutes
  • Less gas consumption & maintenance than anaerobic chambers
  • Faster & more reliable than gas packs

Improve the quality and consistency of your bacterial cultivation

Streamline workflow, save money, and improve the quality and consistency of your growth of anaerobes, microaerophiles, and capnophiles with the Advanced Anoxomat III. Automatically and easily create exact, repeatable environments. It is flexible and easy to use, keeping clinical and industrial microbiology labs productive and ready to culture a wide range of microbes.

Highlighted features
  • Easily Create Custom Environments in 5 Minutes
  • Effective and Rapid Bacterial Recovery in Less Time
  • Add and Remove Plates from Jars and Recreate Environments in Minutes
  • Automatic, One Button Operation
  • Save on Operational Costs

Automatically create exact, repeatable environments

Anoxomat supports quality growth of anaerobic organisms, and microaerophilic and capnophilic bacteria. Accurate bacterial growth needs stable, repeatable environmental conditions requiring gas mixtures to stay within desired values for up to 48 hours. Our quality program ensures you get the right environment as a jar is processed.

Industry Applications

Clinical Microbiology Labs

Create custom, repeatable environments to improve productivity in clinical labs. This allows for faster patient treatment and reduced hospital time.

Biotech Labs

The fast and reliable growth conditions can help ensure maximum quality control.

Food & Beverage Labs

Easily monitor safety standards for food production to meet quality targets.

Product Features

Rapid and robust results

  • Exact, repeatable environmental conditions with gas mixtures within desired values.

Reduces costs and laboratory waste

  • Low gas consumption
  • Substantial operational savings over gas generating sachet systems and chambers
  • Lower cost of ownership

Maximum quality control

  • Automatic quality assurance program prior to each recipe
  • Eliminate guesswork and frustration.

Track & trace compatibility

  • Easy quality control with simplified tracking and tracing
  • Optional barcode scanner & printer

Unmatched flexibility

  • Take plates in and out of anaerobic environments in minutes

Workflow efficiency

  • Automatic, one-button operation

Multi-functional programming

  • Anaerobic, microaerophilic, or custom environment
  • Ability to program recipes with the optional “User-Generated Recipes” function

Backed by comprehensive support

  • Purchase instruments with peace of mind
  • Knowledgeable, experienced, and responsive support team

FAQs

What is the McIntosh & Fildes method?

Anoxomat uses the widely known McIntosh and Fildes system of evacuation and replacement to create anaerobic environments. During the anaerobic evacuation cycle, oxygen within the jar is replaced with hydrogen. After the anaerobic cycle, a mere 0.16% residual oxygen content is left in the jar, which is then removed by the Palladox catalyst. The anaerobic recipe leaves the jar with a strict zero oxygen level and 10% carbon dioxide mix.

You need to increase productivity. But how? Anoxomat is the answer.

  • Automatic quality control system: Anoxomat checks the environment so you don’t waste time incubating jars in an unstable environment.
  • Streamlines workflow: set up jars and return to bench to continue work.
  • Low maintenance: less down time and no disruption to workflow.
  • Process more samples in-house: smaller labs save money.
  • Process up to 4 jars at a time: Get more done in less time.

How does the Anoxomat system compare to gaspak sachet generating methods?

The Anoxomat Jar System creates the environment needed for optimal bacterial growth in minutes. There is no lag in sub-optimal conditions for samples, so you get reliable and consistent environments for anaerobic and microaerophilic testing. The environment created by the Anoxomat contains adequate hydrogen levels needed for growth unlike gaspak systems. Studies observed larger colonies in 51.6% of tests with the Anoxomat system vs. gaspak systems. Download our comparison guide of Anoxomat vs. Gaspak systems.

How fast does it take to create the desired environment with Anoxomat?

The Anoxomat creates the desired environment within minutes so you can get
your anaerobes in the appropriate environment fast! Even the most sensitive bacteria , such as Porph. asacharolytica, saw growth at 48 hours as opposed to 72 hours with gas-generating sachets. You need trusted growth. Accurate bacterial growth require stable, repeatable environmental conditions so gas mixtures stay within desired values for up to 48 hours.

Instrument 100V 110V 220V
--- --- --- ---
Voltage 100-120VAC 100-120VAC 220-240VAC
Frequency 50/60 Hz 60 Hz 50/60 Hz
Power Consumption 516W 516W 516W
Dimensions
Width X Depth X Height: 12 X 9 X 13 in. ( 30.5 X 23 X 33 cm )
Weights Pounds Kilograms
110V and 220V systems
Net: 33.0 15.0
Shipping: 40.0 18.1
100V systems
Net: 36.0 16.3
Temperature and Humidity
Operating Conditions 10 °C to 32 °C, 50 °F to 91 °F
Humidity 20-80% relative humidity (non-condensing)
Storage Conditions 0 °C to 70 °C, 32 °F to 158 °F
Supported languages
Spanish, German, Dutch, French, Simplified Chinese, Japanese, Korean, Russian
Certifications
Installation class: I
Over-voltage category: II
Pollution degree: 2
Moisture protection: IPXO (ordinary)
Warranty
One-year limited warranty on workmanship and
all parts excepty glass, plastic and parts warranted by their makers.
Voltage and Frequency 120V 240V
--- --- ---
Voltage 90-126.5 VAC 198-264 VAC
Frequency 50/60 Hz 50/60 Hz

Supplies & Accessories

AN2BCS Barcode scanner
AN2DI Data interface
AN2GC Additional Gas Connection
AN2ISC1 Registration input screen
AN2JC Additional Jar Connection
AN2PPR Pre-Programmed Recipes
AN2TP1 Recipe printer, Thermal Paper or Medical Grade Paper
AN2TP3 Dot Matrix Printer for Plain Paper
AN2TT Track & Trace Package
AN2UPF User Programming Function
AN3146 Palladox™ disposable sachet, compatible with all jar sizes

Jars

AJ9025 Holds one stack 12 Petri dishes, 9-10 cm dia. Holds one stack of microtiter plates, 13×9 cm dia. Holds one stack of 10 Petri dishes, 14.5 cm.
AJ9028 Holds three stacks of 12 Petri dishes, 9-10 cm dia.
AJ9049 Holds two stacks of 6 Petri dishes, 9-10 cm dia.
AJ9050 Holds two stacks of 12 Petri dishes, 9-10cm dia.

Controllers

ANX1J1G 1 Jar & 1 Gas Connection
ANX1J2G 1 Jar & 2 Gas Connections
ANX1J3G 1 Jar & 3 Gas Connections
ANX2J1G 2 Jar & 2 Gas Connections
ANX2J2G 2 Jar & 2 Gas Connections
ANX2J3G 2 Jar & 3 Gas Connections
ANX3J1G 3 Jar & 1 Gas Connection
ANX3J2G 3 Jar & 2 Gas Connections
ANX4J1G 4 Jar & 1 Gas Connections

Petri Dish Holders

PH 1040 Holds 12 Petri dishes, 9-10 cm dia.
PH 1050 Holds three stacks of 12 Petri dishes, 10 cm dia.
PH 1060 Holds 6 Petri dishes, 9-10 cm dia.
PH 1070 Holds 10 Petri dishes, 14.5 cm dia.
PH 1080 Holds three stacks of 12 Petri dishes, 6 cm dia.
PH 1090 Holds One Stack of Microtiter Plates, 13 x 9 cm dia.
TH0000 For use with AJ9025, holds 14 (16mm tubes)

Product Features

Rapid and robust results

  • Exact, repeatable environmental conditions with gas mixtures within desired values.

Reduces costs and laboratory waste

  • Low gas consumption
  • Substantial operational savings over gas generating sachet systems and chambers
  • Lower cost of ownership

Maximum quality control

  • Automatic quality assurance program prior to each recipe
  • Eliminate guesswork and frustration.

Track & trace compatibility

  • Easy quality control with simplified tracking and tracing
  • Optional barcode scanner & printer

Unmatched flexibility

  • Take plates in and out of anaerobic environments in minutes

Workflow efficiency

  • Automatic, one-button operation

Multi-functional programming

  • Anaerobic, microaerophilic, or custom environment
  • Ability to program recipes with the optional “User-Generated Recipes” function

Backed by comprehensive support

  • Purchase instruments with peace of mind
  • Knowledgeable, experienced, and responsive support team

배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드 결제 (결제링크 문자+이메일 전송)
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0