Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), Alexa Fluor 700, eBioscience
인간 CD3e를 인식하는 UCHT1 단클론 항체로, Alexa Fluor 700으로 표지되어 있습니다. Flow cytometry에 최적화되어 있으며, T세포 표면의 TCR 복합체 분석에 사용됩니다. 4°C 보관, 동결 금지. 연구용으로만 사용 가능합니다.
- 카탈로그번호
- 56-0038-8x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), Alexa Fluor 700, eBioscience
Applications and Tested Dilution
| Application | Tested Dilution | Publications |
|---|---|---|
| Immunohistochemistry (IHC) | - | View 3 publications |
| Immunocytochemistry (ICC/IF) | - | View 1 publication |
| Flow Cytometry (Flow) | 1 µg/test | View 32 publications |
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Published Species | Human, Rat |
| Host / Isotype | Mouse / IgG1, kappa |
| Recommended Isotype Control | Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), Alexa Fluor™ 700, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | UCHT1 |
| Conjugate | Alexa Fluor™ 700 |
| Excitation/Emission Max | 696/719 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_906222 |
Available Formats
- Unconjugated
- Alexa Fluor 532
- Alexa Fluor 561
- Alexa Fluor 660
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV / Violet / Yellow / NovaFluor / PE / Super Bright 시리즈 등 다양한 형광체 옵션 제공
- Request custom conjugation
Product Specific Information
The UCHT1 monoclonal antibody reacts with human CD3e, a 20 kDa subunit of the TCR complex. Along with CD3 gamma and delta, the epsilon chain is essential for proper assembly, trafficking, and surface expression of the TCR complex. CD3 is expressed by thymocytes and all mature T cells. Crosslinking of TCR via immobilized UCHT1 initiates intracellular signaling leading to activation and proliferation.
Applications Reported: Flow cytometric analysis
Applications Tested: Flow cytometry of normal human peripheral blood cells (≤1 µg/test).
A test is defined as the amount of antibody staining a sample in 100 µL volume. Cell number may range from 10⁵–10⁸ cells/test. Optimize concentration for best performance.
Fluorochrome Information:
Alexa Fluor™ 700 emits at 723 nm, excited by red laser (633 nm).
Recommended filter: 685 LP mirror and 710/20 filter.
Ensure instrument compatibility.
Optical Properties:
Excitation: 633–647 nm
Emission: 723 nm
Laser: Red
Filtration: 0.2 µm post-manufacturing filtered
Target Information
The CD3 subunit complex transduces antigen-recognition signals into T cells and regulates TCR surface expression. CD3 subunits (gamma, delta, epsilon, zeta) are immunoglobulin superfamily members encoded on chromosome 11. These subunits associate with cytoplasmic signal transduction molecules via tyrosine-based motifs.
CD3 is expressed on 68–82% of peripheral blood lymphocytes, 65–85% of thymocytes, and Purkinje cells, but not on B or NK cells. Altered expression may occur in autoimmune diseases. Mutations in CD3 genes are associated with CD3 immunodeficiency.
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기