CacheBy
Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, drain ports, two 6-L BPCs
AI 생성AI가 생성·보정한 이미지예요. AI는 실수할 수 있으니 실제 제품과 다를 수 있어요.
1 / 2

Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, drain ports, two 6-L BPCs

상품 한눈에 보기

단일 사용 DHX Heat Exchanger BPC 시스템으로 두 개의 6L 용기 구성. ASI 26/77 폴리에틸렌 필름과 ReadyMate 연결 사용. CIP/SIP 불필요한 멸균 환경 제공. 유지보수 비용 절감 및 병렬 연결로 용량 확장 가능.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 10:43
Thermo Fisher Scientific DX00011I DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, drain ports, two 6-L BPC pk판매 단위 pk ·
재고 확인 필요
689,400원VAT 포함 758,340원

Thermo Fisher Scientific · Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC), ASI 26/77 film, ReadyMate connections, drain ports, two 6-L BPCs

Thermo Fisher Scientific DHX Heat Exchanger BioProcess Container (BPC)

The Thermo Scientific™ DHX™ Heat Exchanger Single-Use BioProcess Container (BPC) is a 2D system consisting of two 6 L BPCs with drain ports. It is composed of Thermo Scientific™ ASI™ 26/77 Polyethylene Film, with interconnecting TPE tubing and ReadyMate DAC end connections.
The DHX Heat Exchanger and DHX BPC each feature a serpentine pattern, creating a sterile fluid path for the process fluid. The BPC fits tightly between the stainless steel DHX Heat Exchanger plate system, and after loading, no further operator interaction is required.
Up to four BPCs can be utilized in a DHX unit.

Features

  • Eliminates post-use cleaning steps required with reusable containers, reducing cross-contamination risks
  • Provides sterile processing environment without CIP/SIP sterilization
  • Minimizes bioburden by addressing weak points in CIP or sanitation systems
  • Reduces maintenance and life cycle costs through unique design
  • Enables increased volume capacity via parallel DHX unit connections

Applications

  • cGMP commercial and clinical biotherapeutics, vaccines, and other biologic processes
  • Upstream: media hold, harvest cooling, harvest hold
  • Downstream: harvest hold, buffers, protein purification, bulk drug substance

Specifications

항목 내용
용량 (미터법) 12 L
구성 Two 6-L BPCs
치수 Each BPC: 62.2 cm × 61.9 cm (24.5 in × 24.4 in)
용도 (장비) DHX1001
필름 설명 ASI™ 26/77
외부 포장 Two 4-mil poly bags
포트 세부 정보 ReadyMate DAC connectors and drain port
물질 Polyethylene
보호용 내부 포장 Protective material around rough areas
배송 조건 Room Temperature
멸균 방법 Gamma Irradiated
제품 라인 DHX
Tubing Style TPE, ID × OD: 0.64 × 12.7 cm (0.25 in × 0.5 in)
Unit Size Each

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.