Thermo Fisher Scientific Syrian Hamster IgG Isotype Control, PE-eFluor 610, eBioscience
Syrian hamster IgG 동형 대조항체로, PE-eFluor 610 형광체가 결합된 폴리클로날 항체입니다. Flow cytometry용 음성 대조로 사용되며, 565/606 nm에서 최적의 형광 특성을 보입니다. 광민감성이 있으므로 어둡게 보관해야 합니다.
- 카탈로그번호
- 61-4914-82
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific Syrian Hamster IgG Isotype Control, PE-eFluor 610, eBioscience
Applications
- Flow Cytometry (Flow): Assay-dependent
- Control (Ctrl): Assay-dependent
Product Specifications
| 항목 | 내용 |
|---|---|
| Host/Isotype | Syrian hamster / IgG |
| Class | Polyclonal |
| Type | Isotype Control |
| Conjugate | PE-eFluor™ 610 |
| Excitation/Emission Max | 565 / 606 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_2648154 |
Product Specific Information
This hamster IgG fraction was purified by affinity chromatography from normal Golden Syrian hamster serum.
This isotype control antibody is reported for use in flow cytometric analysis and tested by flow cytometric analysis of mouse splenocytes. Use isotype control at the same concentration as the experimental antibody.
PE-eFluor® 610 can be excited with laser lines from 488–561 nm and emits at 607 nm.
Recommended filter: 610/20 band pass filter (equivalent to PE-Texas Red®).
Ensure the instrument can detect this fluorochrome.
- Light sensitivity: Tandem dye sensitive to photo-induced oxidation; protect vial and samples from light.
- Fixation: Samples can be stored in IC Fixation Buffer (Product #00-8222) or 1-step Fix/Lyse Solution (Product #00-5333) for up to 3 days at 4°C in the dark with minimal impact on brightness and FRET efficiency.
- Excitation: 488–561 nm
- Emission: 607 nm
- Laser: Blue, Green, Yellow-Green
- Filtration: 0.2 µm post-manufacturing filtered
Target Information
Isotype controls help distinguish non-specific background signal from specific antibody signal.
They have no relevant antigen specificity and are used as negative controls in flow cytometry and other applications such as ChIP, immunohistochemistry, and gel shifts.
Isotype controls should match the species and isotype of the primary antibody, and if directly labeled, should use the same fluorophore for accurate comparison.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.