CacheBy
Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), eFluor 450, eBioscience
원본

Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), eFluor 450, eBioscience

상품 한눈에 보기

Armenian hamster IgG 동형 대조 항체로, 유세포분석(Flow Cytometry)용 음성 대조군으로 사용됩니다. eFluor 450 형광체로 Violet laser(405 nm)에서 여기되어 445 nm에서 방출됩니다. 실험 항체와 동일 농도로 사용하며, 4°C 암소 보관 권장.

카탈로그번호
48-4888-8x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 09:25
Thermo Fisher Scientific 48-4888-82 Armenian Hamster IgG Isotype Control (eBio299Arm), eFluor 450, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
316,800원VAT 포함 348,480원
Thermo Fisher Scientific 48-4888-80 Armenian Hamster IgG Isotype Control (eBio299Arm), eFluor 450, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
146,700원VAT 포함 161,370원

Thermo Fisher Scientific · Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), eFluor 450, eBioscience

Applications

  • Flow Cytometry (Flow): Assay-dependent
  • Control (Ctrl): Assay-dependent

Product Specifications

항목 내용
Host/Isotype Armenian hamster / IgG
Class Monoclonal
Type Isotype Control
Clone eBio299Arm
Conjugate eFluor™ 450
Excitation/Emission Max 405 / 445 nm
Form Liquid
Concentration 0.2 mg/mL
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_1271980

Available Formats

  • Unconjugated
  • Alexa Fluor 488, 532, 660, 700
  • APC, APC-eFluor 780
  • Biotin
  • Brilliant UV 395~805 series
  • Brilliant Violet 421~786 series
  • eFluor 506, 615, 660
  • FITC
  • Functional Grade
  • PE, PE-Cyanine5, PE-Cyanine5.5, PE-Cyanine7
  • PE-eFluor 610
  • PerCP-Cyanine5.5, PerCP-eFluor 710
  • Super Bright 436, 600, 645, 702, 780
  • Request custom conjugation available

Product Specific Information

The eBio299Arm monoclonal antibody is useful as an isotype control immunoglobulin.

  • Applications Reported: Flow cytometric analysis
  • Applications Tested: Tested by flow cytometric analysis of mouse splenocytes
    Use isotype control at the same concentration as the experimental antibody.

eFluor® 450 is an alternative to Pacific Blue®, excited with the Violet laser (405 nm) and emits at 445 nm. Ensure your instrument can detect this fluorochrome.

  • Excitation: 405 nm
  • Emission: 445 nm
  • Laser: Violet Laser
  • Filtration: 0.2 µm post-manufacturing filtered

Target Information

Isotype control antibodies serve as negative controls to help distinguish non-specific background signal from specific antibody signal.
They are typically used in flow cytometry, but also applicable in ChIP, immunohistochemistry, and gel shift assays.

To ensure accurate results, the isotype control should match the species and isotype of the primary antibody.
When using directly labeled primary antibodies, the control should be conjugated with the same label.


For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.