CacheBy
Thermo Fisher Scientific MCP-1 Polyclonal Antibody, Biotin, PeproTech
원본

Thermo Fisher Scientific MCP-1 Polyclonal Antibody, Biotin, PeproTech

상품 한눈에 보기

Biotin으로 표지된 Thermo Fisher MCP-1 (CCL2) 폴리클로날 항체로, 마우스 시료의 MCP-1 검출에 적합합니다. Western blot과 ELISA에서 높은 민감도와 특이성을 제공합니다. 항원 친화 크로마토그래피로 정제되어 신뢰성 높은 결과를 보장합니다.

카탈로그번호
500-P113BT-500UG
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 03. 오전 08:08
Thermo Fisher Scientific 500-P113BT-500UG MCP-1 Polyclonal Antibody, Biotin, PeproTech 500 ug pk판매 단위 pk ·
재고 확인 필요
3,831,800원VAT 포함 4,214,980원

Thermo Fisher Scientific · Thermo Fisher Scientific MCP-1 Polyclonal Antibody, Biotin, PeproTech

Applications and Tested Dilution

Application Tested Dilution Publications
Western Blot (WB) 0.1–0.2 µg/mL -
ELISA 0.25–1.0 µg/mL 1 publication

Product Specifications

항목 내용
Species Reactivity Mouse
Published Species Mouse
Host/Isotype Rabbit
Class Polyclonal
Type Antibody
Immunogen E.coli-derived Recombinant Murine JE/MCP-1 (CCL2)
Conjugate Biotin
Form Lyophilized
Concentration 0.1–1.0 mg/mL
Purification Antigen affinity chromatography
Storage Buffer PBS
Contains No preservative
Storage Conditions -20°C
Shipping Conditions Ambient

Product Specific Information

Amino Acid Sequence of Recombinant Protein:
QPDAVNAPLT CCYSFTSKMI PMSRLESYKR ITSSRCPKEA VVFVTKLKRE VCADPKKEWV QTYIKNLDRN QMRSEPTTLF KTASALRSSA PLNVKLTRKS EANASTTFST TTSSTSVGVT SVTVN

Preparation:
Produced from sera of rabbits immunized with highly pure Recombinant Murine JE/MCP-1 (CCL2). Anti-Murine JE/MCP-1 (CCL2)-specific antibody was purified by affinity chromatography and then biotinylated.

Sandwich ELISA:
To detect Murine JE/MCP-1 (CCL2) by sandwich ELISA (using 100 µL/well antibody solution), a concentration of 0.25–1.0 µg/mL of this antibody is required. This biotinylated polyclonal antibody, in conjunction with PeproTech Polyclonal Anti-Murine JE/MCP-1 (CCL2) (500-P113) as a capture antibody, allows detection of at least 0.2–0.4 ng/well of Recombinant Murine JE/MCP-1 (CCL2).

Western Blot:
To detect mJE(MCP-1) by Western Blot analysis, this antibody can be used at a concentration of 0.1–0.2 µg/mL. When used with compatible secondary reagents, the detection limit for Recombinant mJE(MCP-1) is 1.5–3.0 ng/lane under either reducing or non-reducing conditions.

Package Information:
500-P113BT-1MG will be provided as 2 × 500 µg.


Target Information

This gene is one of several cytokine genes clustered on the q-arm of chromosome 17. Cytokines are secreted proteins involved in immunoregulatory and inflammatory processes. The encoded protein is structurally related to the CXC subfamily of cytokines, characterized by two cysteines separated by one amino acid. It displays chemotactic activity for monocytes and basophils but not for neutrophils or eosinophils. It has been implicated in diseases characterized by monocytic infiltrates, such as psoriasis, rheumatoid arthritis, and atherosclerosis. It binds to chemokine receptors CCR2 and CCR4.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0