상품 옵션 정보
카탈로그 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
RR31100Radleys RR31100 Findenser B24 Cone, B24 Socket - 400mm long ea재고문의ea0-0
RR31102Radleys RR31102 Findenser B29 Cone, B24 Socket - 400mm long ea재고문의ea0-0
RR31104Radleys RR31104 Findenser B19 Cone, B19 Socket - 400mm long ea재고문의ea0-0
RR31105Radleys RR31105 Findenser Mini B24 Cone, B24 Socket - 275mm long ea재고문의ea0-0
RR31107Radleys RR31107 Findenser Mini B19 Cone, B19 Socket - 275mm long ea재고문의ea0-0
RR31109Radleys RR31109 Findenser Mini B14 Cone, B14 Socket - 275mm long ea재고문의ea0-0
RR31200Radleys RR31200 PTFE Adapter B24 Socket to B29 Cone ea재고문의ea0-0
RR31202Radleys RR31202 PTFE Adapter B19 Socket to B24 Cone ea재고문의ea0-0
RR31204Radleys RR31204 PTFE Adapter B19 Socket to B29 Cone ea재고문의ea0-0
RR31206Radleys RR31206 PTFE Adapter B14 Socket to B19 Cone ea재고문의ea0-0
RR31208Radleys RR31208 PTFE Adapter B14 Socket to B24 Cone ea재고문의ea0-0

Site logo

😃 아래 영상 참고하세요^^

Findenser™ Super Air Condenser

Replaces water-cooled condensers in over 95% of common chemistry applications

Findenser saves water and prevents laboratory flooding

No running water Save Money Water Targets
Safer Cleaner Greener
No risk of water leaks and flooding
from running water
Eliminate the cost of water
purchase and disposal
Helps meet sustainable
water reduction targets

Findenser benefits

Findenser saves water and prevents laboratory flooding, by replacing water-cooled condensers in over 95% of common chemistry applications

  • No running water required

    Findenser comprises of an internal glass condenser and an external, finned aluminium jacket, between which a small amount of water is permanently sealed.

  • Replace water-cooled condensers

    The glass condenser design has a greater internal surface area than traditional air condensers, increasing heat transfer capacity.

  • Increased heat transfer

    The finned jacket fits around the glass condenser, further increasing the external surface area.

  • Save water, save money

    The result is a ‘SUPER air condenser’

Findenser saves water and prevents laboratory flooding

How much water are you wasting?

Water is a precious resource. It makes little economic or environmental sense to waste thousands of litres just to cool a single condenser. Whereas Findenser requires no running water to operate.

Patented design


  • Sealed assembly
  • Encapsulated thermofluid for maximised thermal conductivity and heat transfer

Choice of flasks


  • 10 ml to 2 litre flasks
  • Maximum solvent volume 1 litre

Ground glass cone


  • Fits standard tapered glass sockets
  • Choice of sizes

Finned aluminium jacket


  • Excellent thermal conductivity
  • High performance air-cooling
  • Chemical-resistant anodised surface

Easy clamping


  • Use with standard laboratory clamps
  • Clamping kits available

Ground glass socket


  • Accepts standard tapered cones
  • Choice of sizes

Anti-roll design


  • Contoured edges prevent rolling when not in use
  • Prevents damage to aluminium fins

Technical Information


Findenser Findenser Mini
Length x Diameter 400mm x 72mm 275mm x 72mm
Joints B19, B24, B29 B14, B19, B24
Weight 1200g 670g
Inner or wetted parts Borosilicate glass Borosilicate glass
Finned jacket Anodised aluminium Anodised aluminium
Plug and Seal Acetal & HT Silicone Acetal & HT Silicone
Thermofluid Water Water
Max solvent bpt 155˚C 155˚C
Oven drying Max Temp. 60˚C 60˚C
Dishwasher Max Temp. 50˚C 50˚C
Autoclaving Do Not Autoclave Do Not Autoclave
Ambient operating temp. 0˚C to 24˚C 0˚C to 24˚C

The range


Findenser

RR31100 Findenser B24 Cone, B24 Socket
RR31102 Findenser B29 Cone, B24 Socket
RR31104 Findenser B19 Cone, B19 Socket

Findenser Mini

RR31105 Findenser Mini B24 Cone, B24 Socket
RR31107 Findenser Mini B19 Cone, B19 Socket
RR31109 Findenser Mini B14 Cone, B14 Socket

Accessories

RR31200 PTFE Adapter B24 Socket to B29 Cone
RR31202 PTFE Adapter B19 Socket to B24 Cone
RR31204 PTFE Adapter B19 Socket to B29 Cone
RR31206 PTFE Adapter B14 Socket to B19 Cone
RR31208 PTFE Adapter B14 Socket to B24 Cone
RR139139 Right Angle Adapter Ordinary B24 + GL14 + fittings
RR139140 Right Angle Adapter Ordinary B19 + GL14 + fittings
RR139141 Right Angle Adapter Ordinary B14 + GL14 + fittings

Stands and Clamps

RR31210 Retort Stand, 2 Position Base + 12x750mm SS Rod
RR31212 Retort Stand, 2 Position Base
RR31214 Support Rod SS 12x600mm No Thread
RR31216 Support Rod SS 12x750mm No Thread
RR31218 Support Rod SS 12x1000mm No Thread
RR71110 Retort Clamp to 85mm
RR71115 Boss Head to 16mm
RR71120 Support Rod Hotplate Adapter (extension plate)
RR71125 Support Rod SS 13x340mm M10
RR71127 Support Rod SS 13x500mm M10

😃 Case Study

Defense Institute of Advanced Technology

Findenser – an innovative, eco-friendly product to reduce water consumption

GSK Findenser

Findenser helps run overnight experiments without flooding

University of Bath Findenser

Findenser reduces the risk of laboratory floods at Bath University

Roche Findenser

Findenser to reduce total water consumption by 12%

Scottish University Findenser

Findensers are “fantastic”!

University of Cardiff Findenser

Findensers reduce water usage by ~3000 litres per day at the University of Cardiff

Green Cross Company CS1021 Findenser

Improved apparatus set-up using Findenser

Shenzhen Tobacco Industrial co Findenser

Improving safety with Heat-On and Findenser

University of Cambridge Findenser

Replacing traditional water condensers with Findenser to give safer and flexible working conditions

Case Western Reserve Findnser

Findenser – dramatic advantages over water condensers

University of California Findenser

UCSD Chemistry standardises on Findenser for safety and sustainability

Findenser - From hot to cold

From hot to cold, how can I use my Findenser?

Read more

How to optimise the performance of your Findenser

How to optimise the performance of your Findenser

Read more

Sustainable labs

Tips for running a sustainable lab

Read more

Glass of water

World Water Day – The role chemistry must play

Read more

Findenser return on investment

Compared with a single water condenser, running for just 4 hours a day, Findenser will give you a return on your investment in less than one year.

Findenser graph

Average water consumption of common household appliances compared with a Findenser and water condenser

Findenser performance testing

A range of solvents, in identical flasks and set-ups, were tested with a Findenser, water condenser and air condenser to record solvent loss by weight.

Test conditions: 500 ml solvent in 1000 ml flask for 16 hours, heating 10˚C above boiling point for each solvent.

Compared with an air condenser

  • For synthesis with ‘low’ boiling point solvents, Findenser showed a significant improvement in solvent retention.
  • With acetone or DCM the reaction boiled dry when using an air condenser, yet Findenser retained 95% of the solvent under the same conditions.
  • For synthesis with ‘medium’ boiling point solvents, Findenser delivered improved solvent retention particularly with larger volumes and high temperatures.

Compared with a water condenser

Under identical conditions, Findenser retained solvent to the same level (within the limits of experimental error) as a water condenser with a range of solvents. Diethyl ether is not recommended for use with Findenser.

Findenser not only removed the worry of possible flooding but as it doesn’t need to be close to a water source it freed up space.James Lynch, Centre for Sustainable Chemical Technologies, University of Bath

standard findenser range

Findenser

For vessels up to 2 litres in size, with a maximum solvent volume of 1 litre

  • Large size Findenser, 400 mm long.
  • Maximum flask size 2 litres, maximum solvent volume 1 litre.
  • Choice of 3 joint sizes
  • Can be held with conventional laboratory clamps
  • Choice of clamping kits available
  • Range of PTFE adapters available

Mini Findenser

Findenser Mini

For vessels up to 250 ml in size, with a maximum solvent volume of 125 ml

  • Small size Findenser, 275 mm long.
  • Maximum flask size 250 ml, maximum solvent volume 125 ml.
  • Choice of 3 joint sizes
  • Can be held with conventional laboratory clamps
  • Choice of clamping kits available
  • Range of PTFE adapters available

배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드 결제 (결제링크 문자+이메일 전송)
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0