CacheBy
Thermo Fisher Scientific FITC Monoclonal Antibody (NAWESLEE), APC, eBioscience
원본

Thermo Fisher Scientific FITC Monoclonal Antibody (NAWESLEE), APC, eBioscience

상품 한눈에 보기

Thermo Fisher Scientific의 NAWESLEE 단클론 항체는 FITC에 특이적으로 반응하며, Flow Cytometry 및 형광 현미경 분석에 적합합니다. APC 형광체로 결합되어 있으며, 높은 순도의 액상 형태로 제공됩니다. 4°C 암소 보관, 연구용 전용 제품입니다.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 05. 오전 04:07
Thermo Fisher Scientific 17-7691-82 FITC Monoclonal Antibody (NAWESLEE), APC, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
198,500원VAT 포함 218,350원

Thermo Fisher Scientific · Thermo Fisher Scientific FITC Monoclonal Antibody (NAWESLEE), APC, eBioscience

Applications

Immunocytochemistry (ICC/IF)

Flow Cytometry (Flow)

Miscellaneous PubMed (Misc)


Product Specifications

항목 내용
Species Reactivity Chemical
Published Species Chemical
Host / Isotype Mouse / IgG2a, kappa
Recommended Isotype Control Mouse IgG2a kappa Isotype Control (eBM2a), APC, eBioscience™
Class Monoclonal
Type Antibody
Clone NAWESLEE
Conjugate APC
Excitation / Emission Max 651 / 660 nm
Form Liquid
Concentration 0.2 mg/mL
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_2573266

Product Specific Information

This NAWESLEE monoclonal antibody reacts to fluorescein isothiocyanate (FITC), a derivative of fluorescein commonly used in flow cytometry and fluorescent microscopy.
FITC-9 can be used for the separation of cells labeled with FITC-conjugated antibodies or for staining.
Please note that in some instances, the FITC signal can be quenched by the anti-FITC antibody; therefore, this phenomenon should be evaluated empirically.

Applications Reported:
This NAWESLEE antibody has been reported for use in flow cytometric analysis.

Applications Tested:
This NAWESLEE antibody has been tested by flow cytometric analysis of cells stained with FITC-conjugated antibody.
Recommended usage: ≤ 0.125 µg per test.
Higher concentrations may quench FITC fluorescence.
A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL.
Typical cell number per test: 10⁵–10⁸ cells.
Careful titration is recommended for optimal performance.

Optical Properties:
Excitation: 633–647 nm
Emission: 660 nm
Laser: Red Laser

Filtration:
0.2 µm post-manufacturing filtered.


Target Information

FITC (fluorescein isothiocyanate) is a fluorochrome dye that absorbs ultraviolet or blue light, causing molecules to emit visible yellow-green light.
Fluorochrome labeling enables rapid, accurate localization of antigen-antibody interactions.
FITC conjugation is simple and preserves protein activity, making it widely used in immunofluorescent applications.
Anti-FITC antibodies can be used for isolating FITC-labeled cells via magnetic sorting or reducing background signal.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.