Thermo Fisher Scientific FITC Monoclonal Antibody (NAWESLEE), APC, eBioscience
Thermo Fisher Scientific의 NAWESLEE 단클론 항체는 FITC에 특이적으로 반응하며, Flow Cytometry 및 형광 현미경 분석에 적합합니다. APC 형광체로 결합되어 있으며, 높은 순도의 액상 형태로 제공됩니다. 4°C 암소 보관, 연구용 전용 제품입니다.
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific FITC Monoclonal Antibody (NAWESLEE), APC, eBioscience
Applications
Immunocytochemistry (ICC/IF)
- Not tested
View 1 publication
Flow Cytometry (Flow)
- Tested Dilution: 0.125 µg/test
View 1 publication
Miscellaneous PubMed (Misc)
- Not tested
View 1 publication
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Chemical |
| Published Species | Chemical |
| Host / Isotype | Mouse / IgG2a, kappa |
| Recommended Isotype Control | Mouse IgG2a kappa Isotype Control (eBM2a), APC, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | NAWESLEE |
| Conjugate | APC |
| Excitation / Emission Max | 651 / 660 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_2573266 |
Product Specific Information
This NAWESLEE monoclonal antibody reacts to fluorescein isothiocyanate (FITC), a derivative of fluorescein commonly used in flow cytometry and fluorescent microscopy.
FITC-9 can be used for the separation of cells labeled with FITC-conjugated antibodies or for staining.
Please note that in some instances, the FITC signal can be quenched by the anti-FITC antibody; therefore, this phenomenon should be evaluated empirically.
Applications Reported:
This NAWESLEE antibody has been reported for use in flow cytometric analysis.
Applications Tested:
This NAWESLEE antibody has been tested by flow cytometric analysis of cells stained with FITC-conjugated antibody.
Recommended usage: ≤ 0.125 µg per test.
Higher concentrations may quench FITC fluorescence.
A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL.
Typical cell number per test: 10⁵–10⁸ cells.
Careful titration is recommended for optimal performance.
Optical Properties:
Excitation: 633–647 nm
Emission: 660 nm
Laser: Red Laser
Filtration:
0.2 µm post-manufacturing filtered.
Target Information
FITC (fluorescein isothiocyanate) is a fluorochrome dye that absorbs ultraviolet or blue light, causing molecules to emit visible yellow-green light.
Fluorochrome labeling enables rapid, accurate localization of antigen-antibody interactions.
FITC conjugation is simple and preserves protein activity, making it widely used in immunofluorescent applications.
Anti-FITC antibodies can be used for isolating FITC-labeled cells via magnetic sorting or reducing background signal.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.