CacheBy
Thermo Fisher Scientific CD3e Monoclonal Antibody (eBio500A2 (500A2)), PerCP-eFluor 710, eBioscience
원본

Thermo Fisher Scientific CD3e Monoclonal Antibody (eBio500A2 (500A2)), PerCP-eFluor 710, eBioscience

상품 한눈에 보기

마우스 CD3ε 서브유닛을 인식하는 eBio500A2 단클론 항체로, PerCP-eFluor 710 형광체로 결합되어 Flow Cytometry에 최적화됨. 블루 레이저(488 nm)로 여기되어 710 nm에서 방출. T 세포 활성화 연구용으로 사용되며, 4°C 암소 보관.

카탈로그번호
46-0033-8x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 02. 오전 11:17
Thermo Fisher Scientific 46-0033-82 CD3e Monoclonal Antibody (eBio500A2 (500A2)), PerCP-eFluor 710, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
596,300원VAT 포함 655,930원
Thermo Fisher Scientific 46-0033-80 CD3e Monoclonal Antibody (eBio500A2 (500A2)), PerCP-eFluor 710, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
187,500원VAT 포함 206,250원

Thermo Fisher Scientific · Thermo Fisher Scientific CD3e Monoclonal Antibody (eBio500A2 (500A2)), PerCP-eFluor 710, eBioscience

Thermo Fisher Scientific CD3e Monoclonal Antibody (eBio500A2 (500A2)), PerCP-eFluor 710, eBioscience

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 0.125 µg/test
View 5 publications


Product Specifications

항목 내용
Published species Mouse
Host/Isotype Syrian hamster / IgG
Recommended Isotype Control Syrian Hamster IgG Isotype Control, PerCP-eFluor™ 710, eBioscience™
Class Monoclonal
Type Antibody
Clone eBio500A2 (500A2)
Conjugate PerCP-eFluor™ 710
Excitation/Emission Max 482 / 708 nm
Form Liquid
Concentration 0.2 mg/mL
Storage conditions 4°C, store in dark, DO NOT FREEZE!
Shipping conditions Wet ice
RRID AB_10596516

Additional Formats


Product Specific Information

Description:
The eBio500A2 monoclonal antibody reacts with the 25 kD epsilon subunit of the mouse CD3 complex. CD3 subunits gamma, delta and epsilon are required for proper assembly, trafficking and surface expression of the TCR complex. CD3 is expressed by thymocytes in a developmentally regulated manner and by all mature T cells, as well as NKT cells. Binding of eBio500A2 to CD3 initiates the intracellular biochemical pathway resulting in cellular activation and proliferation. The 500A2 antibody can partially cross-block the 17A2 and 145-2C11 antibodies, indicating overlapping epitopes.

Applications Tested:
This antibody has been tested by flow cytometric analysis of mouse splenocytes and can be used at ≤0.125 µg per test (100 µL final volume). Cell number should be determined empirically (10⁵–10⁸ cells/test). Optimize antibody titration for best performance.

Fluorochrome Information:
PerCP-eFluor™ 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.

  • Excitation: 488 nm (Blue Laser)
  • Emission: 710 nm
  • Recommended filters: 685 LP dichroic mirror and 710/40 band pass filter (695/40 acceptable alternative)
    PerCP-eFluor™ 710 conjugated antibodies are stable in 2% formaldehyde overnight at 4°C.
    Filtration: 0.2 µm post-manufacturing filtered.

Target Information

The CD3 subunit complex is crucial in transducing antigen-recognition signals into the cytoplasm of T cells and regulating TCR surface expression. CD3 gamma, delta, epsilon, and zeta subunits are structurally related immunoglobulin superfamily members encoded on chromosome 11. These subunits associate with signal transduction molecules via tyrosine-based motifs. CD3 plays roles in TCR-induced growth arrest, cell survival, and proliferation.
CD3 antigen is found on 68–82% of normal peripheral blood lymphocytes, 65–85% of thymocytes, and Purkinje cells in the cerebellum. Not expressed on B or NK cells. CD3 gene defects are associated with CD3 immunodeficiency.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.