
Thermo Fisher Scientific Phycoerythrin Monoclonal Antibody (eBioPE-DLF), Biotin, eBioscience
Phycoerythrin(PE) 및 PE-Cy5, PE-Cy7에 반응하는 Biotin 결합 단클론 항체. 형광 강도 손실 없이 PE-결합 항체 검출에 적합. Flow cytometry 및 세포 분리 응용에 사용. 0.5 mg/mL 농도의 액상 제품으로 4°C 암소 보관.
- 카탈로그번호
- 13-4120-82
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific Phycoerythrin Monoclonal Antibody (eBioPE-DLF), Biotin, eBioscience
Applications
Immunohistochemistry (IHC)
- Tested dilution: Not specified
- View 1 publication
Flow Cytometry (Flow)
- Tested dilution: 0.06 µg/test
- View 2 publications
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Chemical |
| Published species | - |
| Tag | - |
| Host / Isotype | Mouse / IgG1, kappa |
| Recommended Isotype Control | Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), Biotin, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | eBioPE-DLF |
| Conjugate | Biotin |
| Form | Liquid |
| Concentration | 0.5 mg/mL |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_529611 |
| Filtration | 0.2 µm post-manufacturing filtered |
Additional Formats
Product Specific Information
The eBioPE-DLF monoclonal antibody reacts with phycoerythrin (PE), PE-Cy5, and PE-Cy7, without cross-reactivity to fluorescein (FITC) or allophycocyanin (APC).
When used as a secondary antibody with an appropriate tertiary reagent, it binds PE-conjugated primary antibodies without reducing fluorescent intensity, ensuring no interference or quenching of the PE fluorochrome.
This antibody is suitable for cell separation or staining of PE-labeled cells.
Optimal concentration may vary depending on the density of the primary PE-conjugated antibody and the application.
Applications Reported: Flow cytometric analysis.
Applications Tested: Tested by flow cytometric analysis of mouse splenocytes.
Recommended use ≤ 0.06 µg/test (100 µL final volume). Cell count may range from 10⁵ to 10⁸ cells/test.
Careful titration is recommended for optimal performance.
Target Information
Anti-RPE (R-Phycoerythrin) antibodies are used to bind conjugated primary antibodies without decreasing fluorescent intensity of the RPE fluorochrome.
This method is useful for separation of cells labeled with RPE-conjugated antibodies.
For Research Use Only.
Not for use in diagnostic procedures.
Not for resale without express authorization.
Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.



