CacheBy
Thermo Fisher Scientific APC Monoclonal Antibody (eBioAPC-6A2), Biotin, eBioscience
원본

Thermo Fisher Scientific APC Monoclonal Antibody (eBioAPC-6A2), Biotin, eBioscience

상품 한눈에 보기

APC 및 APC-Cy7에 특이적으로 반응하는 Biotin 결합 단클론 항체로, 형광 강도 저하 없이 APC-결합 항체 검출에 사용 가능. Flow Cytometry에 적합하며 세포 분리 및 염색에 활용. 0.5 mg/mL 액상 형태로 4°C 보관, 동결 금지.

카탈로그번호
13-4170-8x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 09:01
Thermo Fisher Scientific 13-4170-82 APC Monoclonal Antibody (eBioAPC-6A2), Biotin, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
1,014,700원VAT 포함 1,116,170원
Thermo Fisher Scientific 13-4170-80 APC Monoclonal Antibody (eBioAPC-6A2), Biotin, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
227,700원VAT 포함 250,470원

Thermo Fisher Scientific · Thermo Fisher Scientific APC Monoclonal Antibody (eBioAPC-6A2), Biotin, eBioscience

Applications

  • Flow Cytometry (Flow)
    Tested Dilution: 0.015 µg/test

Product Specifications

항목 내용
Host / Isotype Mouse / IgG1
Recommended Isotype Control Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), Biotin, eBioscience™
Class Monoclonal
Type Antibody
Clone eBioAPC-6A2
Conjugate Biotin
Form Liquid
Concentration 0.5 mg/mL
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_657507
Filtration 0.2 µm post-manufacturing filtered

Additional Formats

Product Specific Information

The eBioAPC-6A2 monoclonal antibody reacts with allophycocyanin (APC) and APC-Cy7, showing no cross-reactivity with fluorescein (FITC) or phycoerythrin (PE).
When used as a second-step antibody with an appropriate third step to bind an APC-conjugated primary antibody, it does not decrease the fluorescent intensity of the APC fluorochrome, ensuring no interference or quenching.
This antibody can be used for separation or staining of cells labeled with APC-conjugated antibodies.

Usage Notes:

  • Optimal concentration may vary depending on the density of the primary APC-conjugated antibody and application.
  • Reported application: Flow cytometric analysis.
  • Tested on normal human peripheral blood cells stained with APC-conjugated antibody.
  • Recommended usage ≤ 0.015 µg/test (in 100 µL final volume).
  • Cell number range: 10⁵–10⁸ cells/test.
  • Antibody should be titrated for optimal performance.

Target Information

Anti-APC (Allophycocyanin) antibodies are used to bind APC-conjugated primary antibodies without reducing fluorescent intensity. This enables separation or detection of APC-labeled cells.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.