Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), Alexa Fluor 700, eBioscience
Armenian hamster IgG 동종 대조항체로, Flow Cytometry용 Alexa Fluor 700 결합 단클론 항체입니다. 비특이적 결합 신호를 구분하기 위한 음성 대조용으로 사용됩니다. 633 nm 레이저에 여기되어 723 nm에서 방출됩니다. 연구용으로만 사용 가능합니다.
- 카탈로그번호
- 56-4888-80
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), Alexa Fluor 700, eBioscience
Applications
Tested Dilution
- Flow Cytometry (Flow): Assay-Dependent
- Control (Ctrl): Assay-Dependent
Product Specifications
| 항목 | 내용 |
|---|---|
| Host/Isotype | Armenian hamster / IgG |
| Class | Monoclonal |
| Type | Isotype Control |
| Clone | eBio299Arm |
| Conjugate | Alexa Fluor™ 700 |
| Excitation/Emission Max | 696 / 719 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| Shipping conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_494080 |
Additional Available Formats
- Unconjugated
- Alexa Fluor 488, 532, 660
- APC, APC-eFluor 780
- Biotin
- Brilliant UV 395–805
- Brilliant Violet 421–786
- eFluor 450, 506, 615, 660
- FITC
- Functional Grade
- PE, PE-Cyanine5, PE-Cyanine5.5, PE-Cyanine7, PE-eFluor 610
- PerCP-Cyanine5.5, PerCP-eFluor 710
- Super Bright 436–780
- Custom conjugation available upon request
Product Specific Information
The eBio299Arm monoclonal antibody is an isotype control immunoglobulin suitable for use in flow cytometric analysis.
It has been tested on mouse and human hematopoietic cells. Use the isotype control at the same concentration as the experimental antibody.
Fluorochrome Information:
Alexa Fluor™ 700 emits at 723 nm and can be excited with a 633 nm red laser.
Typical detection setup: 685 LP mirror and 710/20 filter.
Ensure that the instrument supports this fluorochrome.
- Excitation: 633–647 nm
- Emission: 723 nm
- Laser: Red Laser
- Filtration: 0.2 µm post-manufacturing filtered
Target Information
Isotype control antibodies help distinguish non-specific background signal from specific antibody signal.
They are essential in applications such as:
- Flow cytometry (most common)
- Chromatin immunoprecipitation (ChIP)
- Immunohistochemistry
- Gel shift assays
Isotype controls should match the species and isotype of the primary antibody and, when applicable, use the same conjugated label for accurate comparison.
For Research Use Only.
Not for use in diagnostic procedures.
Not for resale without express authorization.