Thermo Fisher Scientific Ly-49G Monoclonal Antibody (AT-8 (AT8)), PE, eBioscience
마우스 Ly-49G 수용체 인식용 단클론 항체로 NK 세포 분석에 적합. Flow cytometry에 최적화되어 있으며 PE 형광 표지. 다양한 마우스 계통에서 반응하며 4°C 암소 보관. 연구용으로만 사용.
- 카탈로그번호
- 12-5885-82
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific Ly-49G Monoclonal Antibody (AT-8 (AT8)), PE, eBioscience
Thermo Fisher Scientific Ly-49G Monoclonal Antibody (AT-8 (AT8)), PE, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 1 µg/test
Publications: View 1 publication
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Published Species | Mouse |
| Host / Isotype | Mouse / IgG2a, kappa |
| Recommended Isotype Control | Mouse IgG2a kappa Isotype Control (eBM2a), PE, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | AT-8 (AT8) |
| Conjugate | PE |
| Excitation / Emission Max | 565 / 576 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_466005 |
Product Specific Information
Description:
The AT8 monoclonal antibody reacts with the mouse Ly-49G receptor from 129, FVB, BALB/c, C3H, CBA, SJL, and A/J strains, but not C57Bl/6 mice. Ly49G, a member of the Ly49 family, is expressed by NK cell subsets.
Applications Reported:
The AT-8 (AT8) antibody has been reported for use in flow cytometric analysis.
Applications Tested:
The AT-8 (AT8) antibody has been tested by flow cytometric analysis of mouse splenocytes. It can be used at ≤1 µg per test (100 µL final volume). Optimal antibody titration is recommended for each assay.
Cell number may range from 10⁵ to 10⁸ cells/test.
Excitation/Emission:
Excitation: 488–561 nm
Emission: 578 nm
Laser: Blue, Green, Yellow-Green
Filtration:
0.2 µm post-manufacturing filtered
Target Information
Mouse Ly49 receptors exhibit allelic specificity for MHC class I Ia molecules and are thought to prevent NK cells from attacking normal cells while allowing attack on infected or transformed cells with down-regulated class I molecules. These inhibitory receptors are also expressed on subpopulations of mouse CD8+ T cells.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.