Thermo Fisher Scientific AmpFLSTR Identifiler Direct PCR Amplification Kit, 1000 Reactions
혈액 및 구강 샘플을 직접 증폭하여 DNA 추출·정제 과정 없이 STR 분석 가능. 고품질 데이터 유지하며 처리 단계 감소로 오염 위험 최소화. 다양한 Applied Biosystems 분석기와 호환되어 고속·자동화 처리에 적합. 1000회 반응용 대용량 키트.
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Applied Biosystems™ AmpFLSTR™ Identifiler™ Direct PCR Amplification Kit
The AmpFLSTR Identifiler Direct PCR Amplification Kit enables direct amplification of 16 loci included in the Identifiler Kit, eliminating the need for DNA extraction or purification steps for DNA database and other single-source reference samples.
Blood or buccal samples on FTA Cards can be directly punched into PCR plates or tubes for amplification without reduction in data quality. Samples collected with the Buccal DNA Collector and other non-FTA substrates can be processed without heat incubation or additional workflow steps using the Applied Biosystems Prep-n-Go Buffer.
Key Features
- Direct amplification of blood and buccal samples without extraction or purification
- High-throughput and automated sample processing
- Reduced contamination risk and procedural errors
- Faster results with maintained data quality
- Lower extraction/purification and labor costs
The Identifiler Direct Kit uses the same dye set, allelic ladder, and primer sequences as the standard Identifiler Kit, which:
- Maximizes concordance with STR profiles from other AmpFLSTR kits (Identifiler, Identifiler Plus, Profiler Plus, Profiler Plus ID, SGM Plus, COfiler)
- Facilitates comparison with casework data and legacy databases
- Streamlines validation and implementation
Performance Data (Table 1)
As part of its rigorous development, the Identifiler Direct Kit was field tested by several medium to high-throughput DNA databasing laboratories to assess “first pass” success rate. Combined results from external test site laboratories are shown below. 1.2 mm punches from blood and buccal samples on FTA Cards and Buccal DNA Collectors were amplified with the Identifiler Direct Kit and analyzed using GeneMapper ID-X at two different minimum peak amplitude thresholds.
| Sample Type | Success Rate (50 rfu Threshold) | Success Rate (150 rfu Threshold) | Number of Samples Tested |
|---|---|---|---|
| Blood on FTA Card | 99.4–100% (Mean: 99.5%) | 95.7–98.8% (Mean: 97.3%) | 414 |
| Buccal on FTA Card | 91.8–99.4% (Mean: 97.1%) | 84.2–95.5% (Mean: 90.9%) | 643 |
| Buccal on Bode Buccal DNA Collector Card | 97.5–98.8% (Mean: 97.8%) | 88.1–98.8% (Mean: 94.0%) | 582 |
The Confidence to Do More
The Identifiler Direct Kit is part of a new generation of AmpFLSTR Kits that harness significant advances in PCR amplification technology to enable recovery of more results from more samples with increased confidence. Laboratories using this kit can significantly expand throughput while ensuring sample integrity and quality assurance.
Complete Validated Solution
This kit is part of a comprehensively validated system for STR-based Human Identification. PCR reaction components, primer sequences, and amplification protocols have been optimized and validated with Applied Biosystems instruments and software to provide robust amplification. Validation experiments were performed according to DAB and SWGDAM guidelines. Each laboratory should perform its own internal validation studies.
The kit is manufactured under ISO 9001 quality system requirements. A Certificate of Analysis is available upon request.
Experience Matters
Applied Biosystems designs and validates reagents, instruments, and software as an integrated system for DNA testing. Technical Service Scientists and Field Application Specialists are available for support and troubleshooting.
Note: For Forensic or Paternity Use Only.
Important Notice
Purchase of this product conveys a non-transferable license for forensic or paternity testing only. It does not include rights for chimerism determination, cell line authentication, cancer analysis, genetic research, or non-casework forensic applications. For additional rights, contact Promega Corp., Madison, WI, USA.
Specifications
| 항목 | 내용 |
|---|---|
| 형식 | Kit |
| 중합효소 | AmpliTaq Gold DNA Polymerase |
| 기술 | STR (Short Tandem Repeat) Analysis |
| 용도(장비) | 310, 3100-Avant, 3130xl, 3500, 3500xL, 3730 Genetic Analyzers, GeneAmp 9600, GeneAmp 9700 |
| 라벨 또는 염료 | FAM, LIZ, NED, PET, VIC |
| 매트릭스 및 크기 표준 | GeneScan 500 LIZ Size Standard, Matrix Standard Set DS-33 |
| 제품라인 | AmpFLSTR, Identifiler |
| 제품 유형 | Direct PCR Amplification Kit |
| 수량 | 1000 Reactions |
| 배송 조건 | Dry Ice |
| 타겟 위치 | D21S11, CSF1PO, vWA, D8S1179, TH01, D18S51, D5S818, D16S539, D3S1358, D2S1338, TPOX, FGA, D7S820, D13S317, D19S433 |
| 용도(애플리케이션) | STR-based Human Identification |
| 반응 형식 | SuperMix or Master Mix |
| 샘플 종류 | Blood, Buccal, DNA (Genomic), Forensic Sample, Saliva, Whatman FTA Cards |
| 크기(최종 제품) | <360 bp |
| 부피 | 25 μL/reaction |
| Unit Size | Each |
🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific Retainer & Base Set (Standard) for 3500 Dx/3500xL Dx Genetic Analyzers, 96 well
509,500원

Thermo Fisher Scientific
Thermo Fisher Scientific Conditioning Reagent for 3500 Dx/3500xL Dx Genetic Analyzers
82,800원

Thermo Fisher Scientific
Thermo Fisher Scientific AmpFLSTR Identifiler Direct PCR Amplification Kit, 1000 Reactions
13,084,700원

Thermo Fisher Scientific
Thermo Fisher Scientific Cathode Buffer Container (CBC), for 3500/SeqStudio Flex
410,600원

Thermo Fisher Scientific
Thermo Fisher Scientific MicroSEQ ID Sequencing Clean-up Plates
472,000원
배송/결제/교환/반품 안내
배송 정보
| 기본 배송비 |
| 교환/반품 배송비 |
|
|---|---|---|---|
| 착불 배송비 |
| ||
| 교환/반품 배송비 |
| ||
결제 및 환불 안내
| 결제수단 |
|
|---|---|
| 취소 |
|
| 반품 |
|
| 환급 |
|
교환 및 반품 접수
| 교환 및 반품 접수 기한 |
|
|---|---|
| 교환 및 반품 접수가 가능한 경우 |
|
| 교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
| 교환 절차 |
|
|---|---|
| 반품 절차 |
|