CacheBy
Thermo Fisher Scientific AmpFLSTR Identifiler Direct PCR Amplification Kit, 1000 Reactions
AI 생성AI가 생성·보정한 이미지예요. AI는 실수할 수 있으니 실제 제품과 다를 수 있어요.
1 / 2

Thermo Fisher Scientific AmpFLSTR Identifiler Direct PCR Amplification Kit, 1000 Reactions

상품 한눈에 보기

혈액 및 구강 샘플을 직접 증폭하여 DNA 추출·정제 과정 없이 STR 분석 가능. 고품질 데이터 유지하며 처리 단계 감소로 오염 위험 최소화. 다양한 Applied Biosystems 분석기와 호환되어 고속·자동화 처리에 적합. 1000회 반응용 대용량 키트.

카탈로그번호
2개 옵션
카테고리
PCR
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 07. 26. 오전 01:04
Thermo Fisher Scientific 4408580 AmpFLSTR Identifiler Direct PCR Amplification Kit, 1000 Reactions Each pk판매 단위 pk ·
재고 확인 필요
57,922,100원VAT 포함 63,714,310원
Thermo Fisher Scientific 4467831 AmpFLSTR Identifiler Direct PCR Amplification Kit, 200 Reactions Each pk판매 단위 pk ·
재고 확인 필요
13,084,700원VAT 포함 14,393,170원

Thermo Fisher Scientific · Thermo Fisher Scientific AmpFLSTR Identifiler Direct PCR Amplification Kit, 1000 Reactions

Applied Biosystems™ AmpFLSTR™ Identifiler™ Direct PCR Amplification Kit

The AmpFLSTR Identifiler Direct PCR Amplification Kit enables direct amplification of 16 loci included in the Identifiler Kit, eliminating the need for DNA extraction or purification steps for DNA database and other single-source reference samples.

Blood or buccal samples on FTA Cards can be directly punched into PCR plates or tubes for amplification without reduction in data quality. Samples collected with the Buccal DNA Collector and other non-FTA substrates can be processed without heat incubation or additional workflow steps using the Applied Biosystems Prep-n-Go Buffer.

Key Features

  • Direct amplification of blood and buccal samples without extraction or purification
  • High-throughput and automated sample processing
  • Reduced contamination risk and procedural errors
  • Faster results with maintained data quality
  • Lower extraction/purification and labor costs

The Identifiler Direct Kit uses the same dye set, allelic ladder, and primer sequences as the standard Identifiler Kit, which:

  • Maximizes concordance with STR profiles from other AmpFLSTR kits (Identifiler, Identifiler Plus, Profiler Plus, Profiler Plus ID, SGM Plus, COfiler)
  • Facilitates comparison with casework data and legacy databases
  • Streamlines validation and implementation

Performance Data (Table 1)

As part of its rigorous development, the Identifiler Direct Kit was field tested by several medium to high-throughput DNA databasing laboratories to assess “first pass” success rate. Combined results from external test site laboratories are shown below. 1.2 mm punches from blood and buccal samples on FTA Cards and Buccal DNA Collectors were amplified with the Identifiler Direct Kit and analyzed using GeneMapper ID-X at two different minimum peak amplitude thresholds.

Sample Type Success Rate (50 rfu Threshold) Success Rate (150 rfu Threshold) Number of Samples Tested
Blood on FTA Card 99.4–100% (Mean: 99.5%) 95.7–98.8% (Mean: 97.3%) 414
Buccal on FTA Card 91.8–99.4% (Mean: 97.1%) 84.2–95.5% (Mean: 90.9%) 643
Buccal on Bode Buccal DNA Collector Card 97.5–98.8% (Mean: 97.8%) 88.1–98.8% (Mean: 94.0%) 582

The Confidence to Do More

The Identifiler Direct Kit is part of a new generation of AmpFLSTR Kits that harness significant advances in PCR amplification technology to enable recovery of more results from more samples with increased confidence. Laboratories using this kit can significantly expand throughput while ensuring sample integrity and quality assurance.

Complete Validated Solution

This kit is part of a comprehensively validated system for STR-based Human Identification. PCR reaction components, primer sequences, and amplification protocols have been optimized and validated with Applied Biosystems instruments and software to provide robust amplification. Validation experiments were performed according to DAB and SWGDAM guidelines. Each laboratory should perform its own internal validation studies.

The kit is manufactured under ISO 9001 quality system requirements. A Certificate of Analysis is available upon request.

Experience Matters

Applied Biosystems designs and validates reagents, instruments, and software as an integrated system for DNA testing. Technical Service Scientists and Field Application Specialists are available for support and troubleshooting.

Note: For Forensic or Paternity Use Only.

Important Notice

Purchase of this product conveys a non-transferable license for forensic or paternity testing only. It does not include rights for chimerism determination, cell line authentication, cancer analysis, genetic research, or non-casework forensic applications. For additional rights, contact Promega Corp., Madison, WI, USA.


Specifications

항목 내용
형식 Kit
중합효소 AmpliTaq Gold DNA Polymerase
기술 STR (Short Tandem Repeat) Analysis
용도(장비) 310, 3100-Avant, 3130xl, 3500, 3500xL, 3730 Genetic Analyzers, GeneAmp 9600, GeneAmp 9700
라벨 또는 염료 FAM, LIZ, NED, PET, VIC
매트릭스 및 크기 표준 GeneScan 500 LIZ Size Standard, Matrix Standard Set DS-33
제품라인 AmpFLSTR, Identifiler
제품 유형 Direct PCR Amplification Kit
수량 1000 Reactions
배송 조건 Dry Ice
타겟 위치 D21S11, CSF1PO, vWA, D8S1179, TH01, D18S51, D5S818, D16S539, D3S1358, D2S1338, TPOX, FGA, D7S820, D13S317, D19S433
용도(애플리케이션) STR-based Human Identification
반응 형식 SuperMix or Master Mix
샘플 종류 Blood, Buccal, DNA (Genomic), Forensic Sample, Saliva, Whatman FTA Cards
크기(최종 제품) <360 bp
부피 25 μL/reaction
Unit Size Each

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.