Thermo Fisher Scientific CD68 Monoclonal Antibody (eBioY1/82A (Y1/82A)), Alexa Fluor 647, eBioscience
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
51-0689-42 | - | Thermo Fisher Scientific 51-0689-42 CD68 Monoclonal Antibody (eBioY1/82A (Y1/82A)), Alexa Fluor 647, eBioscience 100 tests pk | 재고문의 | pk | 508,000원 | - | 558,800원 | |
51-0689-41 | - | Thermo Fisher Scientific 51-0689-41 CD68 Monoclonal Antibody (eBioY1/82A (Y1/82A)), Alexa Fluor 647, eBioscience 25 tests pk | 재고문의 | pk | 225,000원 | - | 247,500원 |
다른 상품 둘러보기
Applications
Tested Dilution
Publications
Immunohistochemistry (IHC)
-
View 5 publications 5 publications
Immunohistochemistry (Paraffin) (IHC (P))
-
View 2 publications 2 publications
Immunocytochemistry (ICC/IF)
-
View 1 publication 1 publication
Flow Cytometry (Flow)
5 µL (0.125 µg)/test
View 12 publications 12 publications
Immunomicroscopy (IM)
-
View 1 publication 1 publication
Product Specifications
Species Reactivity
Human
Published species
Human
Host/Isotype
Mouse / IgG2b, kappa
Recommended Isotype Control
Mouse IgG2b kappa Isotype Control (eBMG2b), Alexa Fluor™ 647, eBioscience™
Class
Monoclonal
Type
Antibody
Clone
eBioY1/82A (Y1/82A)
Conjugate
Alexa Fluor™ 647 Alexa Fluor™ 647 Alexa Fluor™ 647
View additional formats
Excitation/Emission Max
650/671 nm View spectra
Form
Liquid
Concentration
5 µL/Test
Purification
Affinity chromatography
Storage buffer
PBS, pH 7.2, with 0.2% BSA
Contains
0.09% sodium azide
Storage conditions
4° C, store in dark, DO NOT FREEZE!
Shipping conditions
Ambient (domestic); Wet ice (international)
RRID
AB_2848398
Product Specific Information
Description: The eBioY1/82A antibody reacts with CD68 which belongs to the sialomucin family and is closely related to the family of lysosomal-associated membrane proteins (LAMPs) and scavenger receptor. CD68 is predominantly an intracellular protein, found mainly in the late endosomal compartment but can be detected in smaller amounts on the surface of cells of mainly myeloid derived cells; monocytes and macrophages, dendritic cells (and in some Langerhans cells), neutrophils, basophils mast cells, myeloid progenitor cells, and a subset of CD34+ hemopoietic bone marrow progenitor cells. The function has not been fully elucidated but based on its homology and structure suggests a role in antigen processing or presentation and protection of the lysosomal membrane from hydrolytic enzymes. Reports have also seen expression in activated T cells, and about 40% of peripheral blood B-lymphocytes and 50% of all B-ALL.
Staining with eBioY1/82A shows surface staining on B cells and a minor percentage of monocytes while intracellular staining results in about 50% of B cells and most monocytes.
Applications Reported: This eBioY1/82A (Y1/82A) antibody has been reported for use in intracellular staining followed by flow cytometric analysis.
Applications Tested: This eBioY1/82A (Y1/82A) antibody has been pre-diluted and tested by intracellular staining followed by flow cytometric analysis of normal human peripheral blood cells using the Intracellular Fixation & Permeabilization Buffer Set (Product # 88-8824-00) and protocol. Please refer to Staining Intracellular Antigens for Flow Cytometry, Protocol A: Two step protocol for intracellular (cytoplasmic) proteins
located at Flow Protocols. This may be used at 5 µL (0.125 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.
Excitation: 633-647 nm; Emission: 668 nm; Laser: Red Laser.
Target Information
CD68 (Macrosialin) is a 110 kDa integral membrane glycoprotein predominantly expressed on the intracellular lysomsomes of monocytes and macrophages and to a lesser extent by dendritic cells and peripheral blood granulocytes. Also, CD68 could play a role in phagocytic activities of tissue macrophages, both in intracellular lysosomal metabolism and extracellular cell-cell and cell-pathogen interactions. CD68 is expressed by interdigitating reticulum cells in tonsil and some histiocytic lymphoma or histiocytosis, acute myeloid leukemia (AML), and granulocytic sarcoma. Elevated expression of CD68 has been demonstrated on CD34+ cells in various human malignancies, including several Acute Myeloid Leukemia studies.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|