
Thermo Fisher Scientific CD16 Monoclonal Antibody (3G8), NovaFluor Blue 585, eBioscience
인간 및 비인간 영장류 CD16 인식용 단클론 항체로, NovaFluor Blue 585 형광체 결합. Flow Cytometry에 최적화된 사용 가능. CellBlox Plus Blocking Buffer 포함. 488 nm 레이저 기반 형광 분석에 적합. 연구용 전용 제품.
- 카탈로그번호
- H006T0xxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD16 Monoclonal Antibody (3G8), NovaFluor Blue 585, eBioscience
Thermo Fisher Scientific CD16 Monoclonal Antibody (3G8), NovaFluor Blue 585, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.6 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Baboon, Chimpanzee, Cynomolgus monkey, Human, Non-human primate, Rhesus monkey |
| Host/Isotype | Mouse / IgG1 |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 3G8 |
| Conjugate | NovaFluor™ Blue 585 |
| Excitation/Emission Max | 493 / 586 nm |
| Form | Liquid |
| Concentration | 4 µL/Test |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098040 (AB_2896550) |
Additional Formats Available
- APC-eFluor 780
- Functional Grade
- NovaFluor Blue 510, 530, 610-70S, 660-120S, 660-40S, 760
- NovaFluor Red 685, 700, 725, 755
- NovaFluor Yellow 590, 610, 660, 690, 700, 730, 755
- PerCP-eFluor 710
- Super Bright 436, 600, 645, 702
- Request custom conjugation available
Product Specific Information
This 3G8 monoclonal antibody reacts with human and non-human primate CD16, also known as the low-affinity Fc gamma RIII.
CD16 exists as two isoforms, Fc gamma RIIIA and Fc gamma RIIIB.
- Fc gamma RIIIA: expressed on monocytes, macrophages, and NK cells.
- Fc gamma RIIIB: expressed on neutrophils as a GPI-anchored form.
Expression patterns vary among primate species. Binding of IgG triggers signal transduction leading to ADCC, phagocytosis, cytokine release, and antigen presentation.
3G8 recognizes the same epitope as CB16 but binds distinct epitopes compared to B73.1.
Each product includes 1 vial of NovaFluor conjugate and 1 vial of CellBlox Plus Blocking Buffer.
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-diluted and tested on normal human peripheral blood cells.
Use at 5 µL (0.6 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).
NovaFluor Compatibility Note:
NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains instead.
CellBlox Plus Blocking Buffer:
Updated formulation (Cat. No. C001T06F01) required for optimal staining.
Add 5 µL per sample before combining with cells.
For single-color controls, use 5 µL per 100 µL cell sample (10³–10⁸ cells).
NovaFluor Technology:
Based on Phiton technology using nucleic acid dye structures engineered for minimal spillover and spread.
Excitation: 494 nm
Emission: 585 nm
Laser: 488 nm (Blue)
Target Information
CD16 encodes an Fc receptor (FCGR3A) that binds immunoglobulin G and mediates immune complex clearance, ADCC, and viral infection enhancement.
- FCGR3A: expressed on NK cells (transmembrane anchored).
- FCGR3B: expressed on neutrophils (PI linkage).
Mutations are associated with Immunodeficiency 20, Herpes Zoster, and systemic lupus erythematosus susceptibility.
For Research Use Only. Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
