Thermo Fisher Scientific TCR DO11.10 Monoclonal Antibody (KJ1-26 (KJ126, KJI-26, KJI26)), PerCP-eFluor 710, eBioscience
DO11.10 마우스 TCR을 인식하는 KJ1-26 단클론 항체로, Flow Cytometry에 적합. PerCP-eFluor 710 형광체 결합으로 488 nm에서 여기, 710 nm에서 방출. 4°C 암소 보관, 동결 금지. 연구용으로만 사용 가능.
- 카탈로그번호
- 46-5808-8x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific TCR DO11.10 Monoclonal Antibody (KJ1-26 (KJ126, KJI-26, KJI26)), PerCP-eFluor 710, eBioscience
Applications and Tested Dilution
- Application: Flow Cytometry (Flow)
- Tested Dilution: 0.125 µg/test
- View 1 publication
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Published Species | Not Applicable |
| Host / Isotype | Mouse / IgG2a, kappa |
| Recommended Isotype Control | Mouse IgG2a kappa Isotype Control (eBM2a), PerCP-eFluor™ 710, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | KJ1-26 (KJ126, KJI-26, KJI26) |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation / Emission Max | 482 / 708 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_2016636 |
Additional Formats
Product Specific Information
The KJ1-26 anti-idiotypic monoclonal antibody binds the T-cell receptor (TCR) expressed on DO11.10 and DO11.10.24 murine T cell hybridomas, but not on other T cell hybridomas tested. The TCR expressed on DO11.10 recognizes an ovalbumin peptide in the context of I-A^d MHC molecules.
DO11.10 and KJ1-26 have been instrumental in describing many details of T cell immunity.
- Applications Reported: Flow cytometric analysis
- Applications Tested: Tested by flow cytometric analysis of DO.11 cells. Recommended ≤0.125 µg/test (in 100 µL final volume).
- Cell Range: 10⁵–10⁸ cells/test (empirically determined).
- Optimization: Antibody should be titrated for best performance.
Fluorochrome Information
PerCP-eFluor™ 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.
Excitation: 488 nm
Emission: 710 nm
Laser: Blue laser
Recommended Filters: 685 LP dichroic mirror + 710/40 bandpass filter (695/40 acceptable alternative).
PerCP-eFluor™ 710 conjugates are stable after exposure to 2% formaldehyde overnight at 4°C.Filtration: 0.2 µm post-manufacturing filtered.
Target Information
TCR DO11 (DO11.10) is a receptor on lymphocytes of DO11.10 transgenic mice and T-cell receptors of BALB/c-derived DO11.10 and DO11.10.24 hybridomas.
This receptor recognizes an ovalbumin peptide (OVA 323–339) in the context of I-A^d MHC molecules.
Antibodies against DO11.10 have been key in elucidating T cell activation, development, and function.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.