
Thermo Fisher Scientific TIGIT Recombinant Mouse Monoclonal Antibody (MBSA43), Alexa Fluor Plus 647
TIGIT 단백질을 인식하는 마우스 단클론 항체로 Alexa Fluor Plus 647로 표지됨. Flow Cytometry에 최적화되어 있으며 높은 특이성과 일관된 로트 간 재현성을 제공. 658/675 nm 파장에서 우수한 형광 신호를 발현하며, 4°C 암소 보관 권장.
- 카탈로그번호
- 740010MP647x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific TIGIT Recombinant Mouse Monoclonal Antibody (MBSA43), Alexa Fluor Plus 647
Applications and Tested Dilution
| Application | Tested Dilution |
|---|---|
| Flow Cytometry (Flow) | 0.25 µg/test |
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Expression System | Expi293 |
| Class | Recombinant Monoclonal |
| Type | Antibody |
| Clone | MBSA43 |
| Conjugate | Alexa Fluor™ Plus 647 |
| Excitation / Emission Max | 658 / 675 nm |
| Form | Liquid |
| Concentration | 1.0 mg/mL |
| Purification | Protein A/G |
| Storage Buffer | Proprietary buffer, pH 6.5 |
| Contains | 0.008% Bromonitrodioxane, 0.008% Methylisothiazolone |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Wet ice |
| RRID | AB_2942263 |
| Filtration | 0.2 µm post-manufacturing filtered |
Additional Formats
- Unconjugated
- Alexa Fluor Plus 488
- Alexa Fluor Plus 555
- Alexa Fluor Plus 594
- Request custom conjugation
Product Specific Information
Recombinant antibodies are produced using specific genes that code for the desired antibodies. These genes are cloned into an expression vector and expressed in vitro. The advantages of recombinant antibodies include improved specificity and lot-to-lot consistency.
Invitrogen™ Alexa Fluor™ Plus antibodies provide brighter signal compared to traditional Alexa Fluor™ conjugates, offering better signal-to-noise ratios for critical experiments. These antibodies use proprietary dye chemistry for enhanced fluorescent performance.
Usage Notes:
- Centrifuge the protein conjugate solution briefly before use and use only the supernatant to remove aggregates.
- Optimal antibody dilution should be determined empirically.
- Tested application: Flow cytometric analysis of human PBMCs at ≤0.25 µg/test.
- A test is defined as the amount of antibody required to stain a 100 µL cell sample (10⁵–10⁸ cells/test).
- Excitation: 658 nm; Emission: 675 nm; Laser: Red Laser.
Target Information
Binds with high affinity to the poliovirus receptor (PVR), leading to increased IL10 secretion and decreased IL12B secretion. Suppresses T cell activation by promoting the generation of mature immunoregulatory dendritic cells.
For Research Use Only. Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.


