Thermo Fisher Scientific CD3e Monoclonal Antibody (145-2C11), Brilliant Violet 786, eBioscience
마우스 CD3e를 인식하는 145-2C11 클론 단일클론항체로, Brilliant Violet 786 형광체가 결합되어 있습니다. 유세포분석(Flow Cytometry)에 적합하며, T 세포 표지 및 활성화 연구에 활용됩니다. 4°C 암소 보관, 메탄올 고정 비호환.
- 카탈로그번호
- 417-0031-8x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD3e Monoclonal Antibody (145-2C11), Brilliant Violet 786, eBioscience
Applications and Tested Dilution
- Application: Flow Cytometry (Flow)
- Tested Dilution: 1.0 µg/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Host / Isotype | Armenian hamster / IgG |
| Recommended Isotype Control | Armenian Hamster IgG Isotype Control (eBio299Arm), Brilliant Violet™ 786, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 145-2C11 |
| Conjugate | Brilliant Violet™ 786 |
| Excitation / Emission Max | 406 / 788 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2, with BSA |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, Do not freeze |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_2925713 |
Additional Available Formats
- Unconjugated
- Alexa Fluor 488
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV 496 / 563 / 615 / 661 / 737
- Brilliant Violet 421 / 480 / 605 / 650 / 711
- eFluor 450
- FITC
- Functional Grade
- NovaFluor Blue / Red / Yellow series
- PE, PE-Cyanine5/5.5/7, PE-eFluor 610
- PerCP-Cyanine5.5
- Super Bright 436 / 600 / 780
- Request custom conjugation
Product Specific Information
The 145-2C11 monoclonal antibody reacts with mouse CD3e, a 20 kDa subunit of the TCR complex. The epsilon chain is required for proper assembly, trafficking, and surface expression of the TCR complex. CD3 is expressed by thymocytes and mature T cells. Binding of 145-2C11 to TCR can induce activation, proliferation, or apoptosis depending on conditions. Commonly used as a phenotypic marker for mouse T cells.
- Applications Reported: Flow cytometric analysis
- Applications Tested: Tested by flow cytometric analysis of mouse splenocytes (≤1.0 µg/test).
A test is defined as the amount of antibody that stains a 100 µL cell sample. Cell number can range from 10⁵–10⁸ cells/test. Titrate for optimal performance.
Fluorochrome Information:
Brilliant Violet™ 786 (BV786) emits at 786 nm and is suitable for cytometers with a 405 nm violet laser. Ensure instrument compatibility.
Buffer Recommendations:
When using multiple polymer dye-conjugated antibodies, use Super Bright Complete Staining Buffer (SB-4401-42) or Brilliant Stain Buffer™ (00-4409-75) to minimize non-specific interactions.
Light Sensitivity:
Protect from light due to photo-induced oxidation sensitivity.
Fixation:
Samples can be stored in IC Fixation Buffer (00-8222-49) or 1-step Fix/Lyse Solution (00-5333-54) up to 3 days at 4°C in the dark. BV786 is not compatible with methanol-based fixation.
Excitation: 407 nm
Emission: 786 nm
Laser: Violet Laser
BRILLIANT VIOLET™ is a trademark of Becton, Dickinson and Company, used under license. Powered by Sirigen™.
Target Information
The CD3 subunit complex transduces antigen-recognition signals into T cells and regulates TCR complex expression. CD3 subunits (gamma, delta, epsilon, zeta) are immunoglobulin superfamily members encoded on chromosome 11. They associate with cytoplasmic signaling molecules via double tyrosine motifs. CD3 is expressed on 68–82% of peripheral blood lymphocytes, 65–85% of thymocytes, and Purkinje cells, but not on B or NK cells. Defects in CD3 genes can lead to CD3 immunodeficiency.
For Research Use Only. Not for use in diagnostic procedures.