Thermo Fisher Scientific CD11a (LFA-1alpha) Monoclonal Antibody (M17/4), Functional Grade, eBioscience
마우스 CD11a(LFA-1α)를 인식하는 M17/4 단클론 항체로, 림프구 및 과립구의 부착 관련 연구에 적합합니다. Flow cytometry 및 기능적 차단 실험에 사용 가능하며, 0.5 µg/test 권장. 고순도(>90%) 및 저엔도톡신 수준으로 제조되었습니다.
- 카탈로그번호
- 16-0111-xxx (6개 옵션)
- 판매단위
- pk
카탈로그
6개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD11a (LFA-1alpha) Monoclonal Antibody (M17/4), Functional Grade, eBioscience
Applications and Tested Dilution
| Application | Tested Dilution | Publications |
|---|---|---|
| Immunohistochemistry (IHC) | - | View 2 publications |
| Immunocytochemistry (ICC/IF) | - | View 1 publication |
| Flow Cytometry (Flow) | 0.5 µg/test | View 11 publications |
| Neutralization (Neu) | - | View 4 publications |
| Functional Assay (Functional) | Assay-Dependent | View 3 publications |
| Control (Ctrl) | Assay-Dependent | - |
| Inhibition Assays (IA) | - | View 1 publication |
Product Specifications
| 항목 | 내용 |
|---|---|
| Published Species | Mouse |
| Host / Isotype | Rat / IgG2a, kappa |
| Recommended Isotype Control | Rat IgG2a kappa Isotype Control (eBR2a), Functional Grade, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | M17/4 |
| Conjugate | Functional Grade |
| Form | Liquid |
| Concentration | 1 mg/mL |
| Storage Conditions | 4°C |
| Shipping Conditions | Wet ice |
| RRID | AB_2865612 |
Available Formats
- Unconjugated
- APC
- eFluor 450
- FITC
- NovaFluor Blue 610-70S
- NovaFluor Blue 660-120S
- NovaFluor Red 685
- NovaFluor Red 700
- NovaFluor Red 755
- NovaFluor Yellow 610
- NovaFluor Yellow 660
- NovaFluor Yellow 700
- NovaFluor Yellow 755
- PE
- PE-Cyanine7
- PerCP-eFluor 710
- Super Bright 436
- Super Bright 600
- Super Bright 702
- Request custom conjugation
Product Specific Information
Description:
The M17/4 monoclonal antibody reacts with mouse CD11a, the 180 kDa integrin alpha L (LFA-1α). LFA-1, formed by non-covalent association of CD11a with CD18 (integrin β2), is an adhesion molecule involved in lymphocyte and granulocyte function. Ligands include CD54 (ICAM-1), CD102 (ICAM-2), and CD50 (ICAM-3). CD11a is expressed by all leukocytes.
Applications Reported:
- Flow cytometric analysis
- Blocking of CD11a function
Applications Tested:
Tested by flow cytometry using mouse splenocytes. Recommended ≤0.5 µg/test in 100 µL final volume. Cell number: 10⁵–10⁸ cells/test. Titrate for optimal performance.
Storage and Handling:
Use in a sterile environment. Store at 4°C.
Filtration:
0.2 µm post-manufacturing filtered.
Purity:
90% by SDS-PAGE.
Endotoxin Level:
<0.001 ng/µg antibody (LAL assay).
Aggregation:
<10% by HPLC.
Target Information
CD11a (LFA-1α, ITGAL) forms part of the LFA-1 complex with CD18 (αLβ2 integrin). It mediates leukocyte adhesion via ICAM-1, -2, and -3, and participates in lymphocyte costimulatory signaling. CD11a expression is found on leukocyte membranes, shifting from low- to high-affinity conformations upon stimulation. It is critical in immune cell interaction, migration, and T-cell function regulation.
Blocking CD11a is a therapeutic strategy for inflammatory diseases. Humanized anti-CD11a antibody Efalizumab (Raptiva) and CD11a-binding compounds like simvastatin demonstrate immunomodulatory effects. Two transcript variants of CD11a are known. Diseases linked to CD11a dysfunction include benign cephalic histiocytosis and leukocyte adhesion deficiency.
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.
Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.