CacheBy
Thermo Fisher Scientific CXCL12 alpha (SDF-1 alpha) Polyclonal Antibody, Biotin, PeproTech
원본

Thermo Fisher Scientific CXCL12 alpha (SDF-1 alpha) Polyclonal Antibody, Biotin, PeproTech

상품 한눈에 보기

CXCL12 alpha(SDF-1 alpha)에 특이적인 Biotin 결합 Rabbit Polyclonal 항체로, 인간 단백질 검출용. Western blot 및 ELISA에서 높은 민감도. 항원 친화 크로마토그래피로 정제되어 고순도. 연구용으로만 사용 가능.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
ADBIX 2026 전시회10/28~30 코엑스 · 사전등록 안내자세히보기
Thermo Fisher Scientific 500-P87ABT-500UG CXCL12 alpha (SDF-1 alpha) Polyclonal Antibody, Biotin, PeproTech 500 ug pk판매 단위 pk
재고 확인 필요
3,831,800원VAT 포함 4,214,980원

Thermo Fisher Scientific · Thermo Fisher Scientific CXCL12 alpha (SDF-1 alpha) Polyclonal Antibody, Biotin, PeproTech

Thermo Fisher Scientific CXCL12 alpha (SDF-1 alpha) Polyclonal Antibody, Biotin, PeproTech

Applications and Tested Dilutions

Application Tested Dilution Publications
Western Blot (WB) 0.1–0.2 µg/mL View 1 publication
ELISA 0.25–1.0 µg/mL View 2 publications

Product Specifications

Specification Description
Species Reactivity Human
Published Species Bovine, Human
Host/Isotype Rabbit
Class Polyclonal
Type Antibody
Immunogen E.coli-derived, 8.0 kDa Recombinant Human SDF-1alpha (CXCL12)
Conjugate Biotin
Form Lyophilized
Concentration 0.1–1.0 mg/mL
Purification Antigen affinity chromatography
Storage Buffer PBS
Contains No preservative
Storage Conditions -20°C
Shipping Conditions Ambient

Product Specific Information

AA Sequence of recombinant protein:
KPVSLSYRCP CRFFESHVAR ANVKHLKILN TPNCALQIVA RLKNNNRQVC IDPKLKWIQE YLEKALNK

Preparation:
Produced from sera of rabbits immunized with highly pure Recombinant Human SDF-1alpha (CXCL12). Anti-Human SDF-1alpha (CXCL12)-specific antibody was purified by affinity chromatography and then biotinylated.

Sandwich ELISA:
For detection of Human SDF-1alpha by sandwich ELISA (using 100 µL/well antibody solution), a concentration of 0.25–1.0 µg/mL is required. This biotinylated polyclonal antibody, in conjunction with PeproTech Polyclonal Anti-Human SDF-1alpha (500-P87A) as a capture antibody, allows detection of at least 0.2–0.4 ng/well of Recombinant Human SDF-1alpha.

Western Blot:
For detection of Human SDF-1alpha by Western Blot, use at 0.1–0.2 µg/mL. When used with compatible secondary reagents, the detection limit for Recombinant Human SDF-1alpha is 1.5–3.0 ng/lane under either reducing or non-reducing conditions.

Packaging:
500-P87ABT-1MG supplied as 2 × 500 µg.


Target Information

CXCL12 is a stromal cell-derived alpha chemokine member of the intercrine family. This gene product and its receptor CXCR4 can activate lymphocytes and have been implicated in the metastasis of cancers such as breast cancer. Mutations in this gene are associated with resistance to HIV-1 infections. Multiple transcript variants encoding different isoforms have been identified.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0개

아직 등록된 문의가 없어요.