CacheBy
Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Blue 760, eBioscience
원본

Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Blue 760, eBioscience

상품 한눈에 보기

인간 CD3 항원을 인식하는 UCHT1 클론 단일클론 항체로, NovaFluor Blue 760 형광체로 표지되어 있습니다. 유세포분석(Flow Cytometry)에 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 사용 시 최적의 염색 결과를 제공합니다. 연구용으로만 사용 가능합니다.

카탈로그번호
H002T0xxxxxx (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 10:48
Thermo Fisher Scientific H002T03B11-A CD3 Monoclonal Antibody (UCHT1), NovaFluor Blue 760, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
653,000원VAT 포함 718,300원
Thermo Fisher Scientific H002T02B11-A CD3 Monoclonal Antibody (UCHT1), NovaFluor Blue 760, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
294,300원VAT 포함 323,730원

Thermo Fisher Scientific · Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Blue 760, eBioscience

Applications

  • Flow Cytometry (Flow): 5 µL (0.8 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Mouse / IgG1, kappa
Class Monoclonal
Type Antibody
Clone UCHT1
Conjugate NovaFluor™ Blue 760
Excitation / Emission Max 490 / 764 nm
Form Liquid
Concentration 0.8 µg/test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3099384

Additional Available Formats

  • Unconjugated
  • Alexa Fluor 532, 561, 660, 700
  • APC, APC-eFluor 780
  • Biotin
  • Brilliant UV/Violet/Yellow series
  • eFluor 450, 506
  • FITC
  • PE, PE-Cyanine5, PE-Cyanine7
  • Super Bright 436–780
  • NovaFluor Blue/Red/Violet/Yellow variants
  • Request custom conjugation

Product Specific Information

Description:
The OKT8 monoclonal antibody reacts with the human CD8a molecule, a 32–34 kDa cell surface receptor expressed on thymocytes and subsets of mature T and NK cells. CD8 binds to MHC class I and associates with protein tyrosine kinase p56lck, playing a role in T-cell development and activation.

Applications Reported:
Validated for flow cytometric analysis.

Applications Tested:
Pre-titrated and tested for flow cytometry on normal human peripheral blood cells. Recommended usage is 5 µL (0.8 µg) per test in a final volume of 100 µL.

Compatibility Notes:

  • NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
  • Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for optimal results.

Blocking Buffer Recommendation:
This conjugate ships with CellBlox Plus Blocking Buffer (Product # C001T06F01), which should be used for all experiments involving NovaFluor conjugates.

  • Add 5 µL per sample (regardless of number of NovaFluor dyes).
  • For single-color controls, use 5 µL per 100 µL of cell sample (10³–10⁸ cells).

Technology:
NovaFluor conjugates utilize Phiton™ technology, based on nucleic acid dye structures that provide engineered fluorescent signatures designed to minimize spillover and spread.

Excitation / Emission / Laser:
492 nm / 766 nm / 488 nm (Blue laser)

Target Information

The CD3 subunit complex transduces antigen-recognition signals into T cells and regulates TCR complex expression. CD3 subunits (gamma, delta, epsilon, zeta) are structurally related immunoglobulin superfamily members encoded on chromosome 11. CD3 is expressed on 68–82% of normal peripheral blood lymphocytes and thymocytes but not on B or NK cells. Defects in CD3 genes are associated with CD3 immunodeficiency.


For Research Use Only. Not for use in diagnostic procedures or resale without authorization.