CacheBy
Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 660, eBioscience
원본

Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 660, eBioscience

상품 한눈에 보기

인간 CD3e를 인식하는 UCHT1 단클론 항체로, NovaFluor Red 660 형광체가 결합되어 있습니다. 유세포분석(Flow Cytometry)에 최적화되어 있으며, 4°C에서 보관하고 동결 금지입니다. T 세포 표면 CD3 복합체 연구에 적합합니다.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 04:30
Thermo Fisher Scientific H002T03R01 CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 660, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
794,700원VAT 포함 874,170원
Thermo Fisher Scientific H002T02R01 CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 660, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
360,000원VAT 포함 396,000원

Thermo Fisher Scientific · Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 660, eBioscience

Applications

  • Flow Cytometry (Flow): 4 µL (0.6 µg)/test

Product Specifications

항목 내용
Host/Isotype Mouse / IgG1, kappa
Class Monoclonal
Type Antibody
Clone UCHT1
Conjugate NovaFluor™ Red 660
Excitation/Emission Max 637/658 nm
Form Liquid
Concentration 4 µL/Test
Storage conditions 4°C, store in dark, DO NOT FREEZE
Shipping conditions Ambient (domestic); Wet ice (international)
RRID AB_2896403

Additional Available Formats

  • Unconjugated
  • Alexa Fluor 532, 561, 660, 700
  • APC, APC-eFluor 780
  • Biotin, Brilliant UV/Violet Series
  • eFluor 450, 506
  • FITC, PE, PE-Cyanine5, PE-Cyanine7
  • Super Bright Series
  • NovaFluor Blue, Red, Violet, Yellow Series
  • Request custom conjugation available

Product Specific Information

Description:
The UCHT1 monoclonal antibody reacts with human CD3e, a 20 kDa subunit of the TCR complex. The epsilon chain, along with gamma and delta subunits, is essential for proper assembly, trafficking, and surface expression of the TCR complex. CD3 is expressed by thymocytes and all mature T cells. Crosslinking of TCR with immobilized UCHT1 induces intracellular signaling leading to T cell activation and proliferation.

Applications Reported:

  • Flow cytometric analysis

Applications Tested:

  • Pre-titrated and validated for flow cytometric analysis of normal human peripheral blood cells
  • Recommended use: 4 µL (0.6 µg) per 100 µL test volume
  • Suitable for 10⁵–10⁸ cells/test

NovaFluor Compatibility Note:
NovaFluor dyes are not compatible with DNA intercalating viability dyes such as propidium iodide, 7-AAD, and DAPI.
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains instead.

Staining Recommendations:
Each NovaFluor conjugate or kit is shipped with CellBlox Blocking Buffer.

  • Add 5 µL per sample when staining with NovaFluor conjugates
  • For single-color controls: add 5 µL per 100 µL of cell sample (10³–10⁸ cells)

Excitation/Emission:

  • Excitation: 637 nm
  • Emission: 659 nm
  • Laser: 633–640 nm (Red)

Technology:
NovaFluor conjugates use Phiton™ technology, employing nucleic acid dye structures engineered for optimized fluorescence signatures with reduced spillover and spread.


Target Information

The CD3 subunit complex transduces antigen-recognition signals into T cell cytoplasm and regulates TCR surface expression.
The complex includes CD3 gamma, delta, epsilon, and zeta subunits, all members of the immunoglobulin superfamily encoded on human chromosome 11.

Biological Roles:

  • Mediates TCR-induced activation, proliferation, and survival
  • Present on 68–82% of peripheral blood lymphocytes and 65–85% of thymocytes
  • Absent on B and NK cells
  • CD3 gene defects are associated with CD3 immunodeficiency

For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.