CacheBy
Thermo Fisher Scientific Kappa Light Chain Monoclonal Antibody (TB28-2), PE, eBioscience
원본

Thermo Fisher Scientific Kappa Light Chain Monoclonal Antibody (TB28-2), PE, eBioscience

상품 한눈에 보기

인간 카파 경쇄를 인식하는 단클론 항체로, 유세포 분석용으로 최적화됨. PE 형광 표지로 565/576 nm에서 여기/방출. 친화 크로마토그래피로 정제되었으며 4°C 암소 보관. 연구용으로만 사용 가능.

카탈로그번호
12-9970-42
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 01. 오후 07:19
Thermo Fisher Scientific 12-9970-42 Kappa Light Chain Monoclonal Antibody (TB28-2), PE, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
385,200원VAT 포함 423,720원

Thermo Fisher Scientific · Thermo Fisher Scientific Kappa Light Chain Monoclonal Antibody (TB28-2), PE, eBioscience

Applications and Tested Dilution

Flow Cytometry (Flow)


Product Specifications

항목 내용
Species Reactivity Human
Published Species Human, Mouse
Host / Isotype Mouse / IgG1, kappa
Recommended Isotype Control Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), PE, eBioscience™
Class Monoclonal
Type Antibody
Clone TB28-2
Conjugate PE
Excitation / Emission Max 565 / 576 nm
Form Liquid
Concentration 5 µL/Test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_10597908

Product Specific Information

The monoclonal antibody TB28-2 recognizes the kappa light chain of human immunoglobulin (~22 kDa), composed of one variable and one constant region. Two kappa chains with heavy chains form the complete immunoglobulin structure. Ig kappa expression is typically found on more than half of B lymphocytes.

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and validated for flow cytometric analysis of normal human peripheral blood cells.
Recommended use: 5 µL (0.5 µg) per test (in 100 µL final volume).
Cell number: 10⁵–10⁸ cells/test (empirically determined).

Fluorescence properties:

  • Excitation: 488–561 nm
  • Emission: 578 nm
  • Compatible Lasers: Blue, Green, Yellow-Green
  • Filtration: 0.2 µm post-manufacturing filtered

Target Information

Immunoglobulins share a basic structure of two heavy and two light chains (kappa or lambda, ~22.5 kDa each). Kappa and lambda chains differ in constant region antigenicity, with a typical kappa:lambda ratio of 70:30.
Antibodies to the kappa light chain are useful for identifying leukemias, plasmacytomas, and certain non-Hodgkin’s lymphomas. Demonstration of clonality in lymphoid infiltrates suggests malignancy.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.