CacheBy
Thermo Fisher Scientific DNA ligase IV Polyclonal Antibody
원본

Thermo Fisher Scientific DNA ligase IV Polyclonal Antibody

상품 한눈에 보기

DNA ligase IV 단백질을 인식하는 Rabbit Polyclonal 항체로, WB, IHC, ICC/IF에 사용 가능. 인간, 마우스, 랫트 반응성. 항원 친화 크로마토그래피로 정제된 액상 항체로, 4°C 단기 보관 및 -20°C 장기 보관 권장.

카탈로그번호
PA528903
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 04:13
Thermo Fisher Scientific PA528903 DNA ligase IV Polyclonal Antibody 100 ul pk판매 단위 pk ·
재고 확인 필요
660,800원VAT 포함 726,880원

Thermo Fisher Scientific · Thermo Fisher Scientific DNA ligase IV Polyclonal Antibody

Applications and Tested Dilutions

Application Tested Dilution
Western Blot (WB) 1:500–1:3,000
Immunohistochemistry (Paraffin) (IHC (P)) 1:100–1:1,000
Immunocytochemistry (ICC/IF) 1:100–1:1,000

Product Specifications

Specification Description
Species Reactivity Human, Mouse, Rat
Host / Isotype Rabbit / IgG
Class Polyclonal
Type Antibody
Immunogen Recombinant fragment corresponding to a region within amino acids 558–823 of Human DNA ligase IV
Conjugate Unconjugated
Form Liquid
Concentration 1 mg/mL
Purification Antigen affinity chromatography
Storage Buffer 0.1M Tris glycine, pH 7, with 20% glycerol
Contains 0.01% thimerosal
Storage Conditions Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Shipping Conditions Wet ice
RRID AB_2546379

Product Specific Information

  • Recommended positive controls: U87-MG, mouse brain, rat brain
  • Predicted reactivity: Mouse (82%), Rat (81%), Sheep (83%), Bovine (86%)
  • Store product as a concentrated solution. Centrifuge briefly prior to opening the vial.

Target Information

The DNA ligase IV protein joins single-strand breaks in double-stranded DNA in an ATP-dependent reaction. It is essential for V(D)J recombination and DNA double-strand break repair via nonhomologous end joining (NHEJ). The protein forms a complex with XRCC4 and interacts with DNA-dependent protein kinase (DNA-PK), both required for NHEJ. Defects in this gene cause LIG4 syndrome. Alternatively spliced transcript variants encoding the same protein have been observed.

Safety Information

WARNING: This product can expose you to chemicals including mercury, which is known to the State of California to cause birth defects or other reproductive harm.
For more information, visit www.P65Warnings.ca.gov.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.