
Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), eFluor 450, eBioscience
인간 CD45 모든 아이소폼을 인식하는 2D1 단클론 항체로, 유세포분석용으로 최적화되어 있습니다. eFluor 450 형광체 결합으로 405 nm 레이저에서 445 nm 방출을 가지며, 고순도 친화 크로마토그래피 정제 제품입니다. 연구용으로만 사용됩니다.
- 카탈로그번호
- 48-9459-4x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), eFluor 450, eBioscience
Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), eFluor 450, eBioscience
Applications
- Flow Cytometry (Flow): 5 µL (0.25 µg)/test
View 21 publications
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Published Species | Human, Non-human primate |
| Host / Isotype | Mouse / IgG1, kappa |
| Recommended Isotype Control | Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), eFluor™ 450 |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 2D1 |
| Conjugate | eFluor™ 450 |
| Excitation / Emission Max | 405 / 445 nm |
| Form | Liquid |
| Concentration | 5 µL/test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2, with 0.2% BSA |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_1603242 |
Additional Formats
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Brilliant Violet 711
- FITC
- NovaFluor Blue 510, 585, 610-30S, 610-70S, 660-120S, 660-40S, 690, 725, 760, 800
- NovaFluor Red 660, 685, 700, 710, 725, 755
- NovaFluor UV 765
- NovaFluor Violet 690, 800
- NovaFluor Yellow 590, 610, 660, 700, 730, 755, 810
- PE, PE-Cyanine7, PE-eFluor 610
- PerCP-Cyanine5.5
- Super Bright 436, 600, 645, 780
- Request custom conjugation available
Product Specific Information
The 2D1 monoclonal antibody reacts with all isoforms of human CD45 (Leukocyte Common Antigen, LCA). CD45 is expressed by all hematopoietic cells except erythrocytes and platelets. The cytoplasmic domain has tyrosine phosphatase activity and is crucial for lymphocyte activation.
- Applications Reported: Flow cytometric analysis
- Applications Tested: Pre-titrated and validated for flow cytometry using human peripheral blood cells
- Recommended Usage: 5 µL (0.25 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test)
Fluorochrome Info:
eFluor® 450 is an alternative to Pacific Blue®, excited at 405 nm and emits at 445 nm. Ensure instrument compatibility.
Filtration: 0.2 µm post-manufacturing filtered
Target Information
CD45 (LCA) is a receptor-type protein tyrosine phosphatase expressed on all nucleated hematopoietic cells (~10% of lymphocyte surface proteins). Absent in non-hematopoietic tissues, CD45 regulates Src-family kinases and JAK kinases, influencing lymphocyte activation, cytokine signaling, and apoptosis. Isoforms differ by alternative splicing and cell type-specific expression.
For Research Use Only. Not for use in diagnostic procedures.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.

