CacheBy
Thermo Fisher Scientific CD3 Monoclonal Antibody (eBioG4.18 (G4.18)), PerCP-eFluor 710, eBioscience
원본

Thermo Fisher Scientific CD3 Monoclonal Antibody (eBioG4.18 (G4.18)), PerCP-eFluor 710, eBioscience

상품 한눈에 보기

쥐 CD3 단백질을 인식하는 단클론 항체로 T세포 표지 및 활성화 연구에 적합. PerCP-eFluor 710 형광체 결합으로 유세포분석(Flow Cytometry)에 최적화. 488 nm 레이저로 여기, 710 nm에서 방출. 4°C 암소 보관, 동결 금지.

카탈로그번호
46-0030-82
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 08:53
Thermo Fisher Scientific 46-0030-82 CD3 Monoclonal Antibody (eBioG4.18 (G4.18)), PerCP-eFluor 710, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
500,500원VAT 포함 550,550원

Thermo Fisher Scientific · Thermo Fisher Scientific CD3 Monoclonal Antibody (eBioG4.18 (G4.18)), PerCP-eFluor 710, eBioscience

Applications


Product Specifications

항목 내용
Species Reactivity Rat
Published Species Mouse, Rat
Host / Isotype Mouse / IgG3, kappa
Class Monoclonal
Type Antibody
Clone eBioG4.18 (G4.18)
Conjugate PerCP-eFluor™ 710
Excitation / Emission Max 482 / 708 nm
Form Liquid
Concentration 0.2 mg/mL
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE!
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_2573666

Available Formats


Product Specific Information

The eBioG4.18 monoclonal antibody recognizes the rat CD3 protein, a critical component of the T-cell receptor (TCR) complex and a marker of T-cell lineage. CD3 participates in signal transduction from the TCR to the nucleus, inducing IL-2 transcription and clonal expansion.

  • In vitro: Immobilized G4.18 activates T cells; soluble form inhibits allogeneic responses and cytotoxicity.
  • In vivo: Demonstrated to induce long-term specific tolerance to organ allografts.
  • Applications Reported: Flow cytometric analysis.
  • Applications Tested: Tested on rat splenocytes at ≤0.5 µg/test (100 µL final volume, 10⁵–10⁸ cells/test). Optimize titration for best performance.

Fluorochrome Characteristics

  • PerCP-eFluor® 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.
  • Excitation: 488 nm (Blue Laser)
  • Emission: 710 nm
  • Recommended filters: 685 LP dichroic mirror and 710/40 band pass (695/40 acceptable alternative).
  • Stable with 2% formaldehyde fixation overnight at 4°C.
  • 0.2 µm post-manufacturing filtered.

Target Information

CD3 is a subunit complex essential for transducing antigen-recognition signals in T cells and regulating TCR surface expression. It includes CD3 gamma, delta, epsilon, and zeta subunits—structurally related immunoglobulin superfamily members encoded on human chromosome 11.

  • Mediates signal transduction via double tyrosine-based motifs.
  • Expressed on 68–82% of peripheral blood lymphocytes, 65–85% of thymocytes, and Purkinje cells.
  • Absent on B and NK cells.
  • Decreased T lymphocyte percentages may occur in autoimmune diseases.
  • CD3 gene defects are associated with CD3 immunodeficiency.

For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.


제품 이미지

Spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.